14
INSTALLATION, EXCHANGE AND CYLINDERS RESET
The check of the nozzle obstruction is done with a little air flow, while a sensor check the pressure of the internal circuit.
In case the sensor detect an increase of the internal pressure, means that there is an obstruction inside the nozzle.
As consequence of the detection, the tamper output will be activated, the buzzer will emit a sound with a fast frequency with
the flash of the red LEDs.
This condition of the alarm will continue until the system is disarmed and armed again.
As the little compressor that introduces the air flow emits some vibrations, its activation occurs only in the following cases:
- When you press the RESET button for more than 5 seconds, besides the activations of the motors, will start a cycle of
monitoring of 15 minutes, in order to simulate the obstruction and check the correct working.
- When the system is armed the cycle of monitoring starts. This cycle is the most important, because as the system was
disarmed probably was easier to go near the machine and obstruct the nozzle. After 15 minutes, the compressor will stop
automatically. If the system is disarmed and armed again, the cycle will start again for 15 minutes.
- After the emission of the fog, as normally the zone where the machine is installed is the last where the visibility is reduced,
the generator remains vulnerable, giving the possibility to the intruder to attempt the sabotage. For this reason, after the
emission of the fog the compressor will be activated for 15 minutes.
The cylinders for FAST 01 2C PRO PLUS are guaranteed to work until the expiry date that is printed on the top.
N.B. When you close the door, the buzzer will make a sound to confirm the tamper is closed.
Attention: before opening the side door, make sure that the alarm control panel is in “service”
mode, so that the opening of the “anti-sabotage or tamper” circuit does not cause any alarm.
After that date, cylinders should be changed even if they have not been used.
It Is recommend to return them to your dealer, who will take care of disposal.
After removing the screws of the door, is sufficient to remove the cylinder and reset the
LED of empty cylinder. After that, insert a new cylinder until you hear the “click” of the
plastic support entering in its housing, then close the door.
If the cylinder seems to be “stuck” in the upper part DO NOT pull with force, make a
pressure with two fingers on top of the cylinder, as to lower it. Then, try to remove it again.
If the cylinder does not enter, check if the cylinder plate of the motor remains
lifted. In case of an empty cylinder to be replaced, it is recommended to replace
it with the second cylinder still full present in the machine, and a new cylinder
will replace this last one.
This in order to ensure a proper rotation of the cylinders and to avoid that a cylinder can
remain unused for a long time within the device.
13
NOZZLE TAMPER
Do not obstruct the nozzle when the generator is armed and cylinders are in.