J1—Terminal Board for Master Card cont.) Terminals (cont.)
5 -
“Closing Safety Device” This is a normally closed terminal where by any
device (i.e. photocells, sensitive edge, magnetic loops) which, if there is an
obstacle in the area they protect during closing, reverses gate direction to
opening.
If the closing safety devices are tripped when the gate is open, they prevent
the leaf movement.
IMPORTANT:
If a connection is not made from this terminal to one of
the - (negative) terminals (i.e. 12, 13, 14, 15) gate closing will not
commence..
6 -
“Slave Control Board Connection” This is a connection between the master
and slave control board. It enables communication between the two
equipment and supplies power to charge the battery on the slave side.
Use
this in conjunction with terminal 15 - (negative). Terminal 6
must
connect with the
right side
of J2 on the slave board,
Terminal 15
must
connect with the
left side
of J2 on the slave board.
Caution!
Do not reverse polarity of the wires connecting the master and
slave board! This will cause permanent damage to both boards and will
void the warranty.
Caution!
7, 8 -
“Positive (7) & (8) 24 Voltage” Positive 24V for powering accessories
that are run by 24V DC power (i.e. locks, safety devices) while the gate
is in motion.
9
-
“Indicator Light” When used with terminal
11,
this terminal grounds the
indicator light.
To avoid compromising correct operation of the system,
do not exceed the indicated power (12V .5Wmax).
The indicator light is lit
during open, opening and blocked. The indicator is flashing during closing.
10
-
“Lamp” When used with terminal
11 ,
this terminal grounds the flashing
lamp out-put.
To avoid compromising correct operation of the system,
do not exceed the indicated power (12V 21Wmax).
When the gate is in
motion, the lamp will flash.
11
-
“Positive 12 Voltage” This is a 12V terminal used to power the indicator
light, lamp (must be connected to the appropriate ground) and constantly
powered accessory devices (when connected to a ground 12,13,14,15)
controlled by 12V DC.
(12V 21Wmax)
12, 13, 14 ,15 -
“Negatives” Interchangeable negative terminals for use with
powered accessories, safety devices and opening devices.