3.
For a Dual gate opener unit, charge the slave board by wiring it to the
master board terminal strip. [terminal 6 of the master
must
connect with
the right side of J2 on the slave and terminal 15 of the master
must
connect with the left side of the slave] (fig 3)
NEVER CONNECT POWER FROM ANY SOURCE DIRECTLY TO
THE SLAVE BOARD. The slave board may ONLY be connected
to the Master control board.
Let the unit charge for 12 hours, after remove both the transformer
power and the battery. You can now proceed with the installation
process.