Programming The Gate Control Panel
Using the following procedures you can change factory settings
such as auto close, speed, force, delays and more.
Begin the programming process by pressing
P1.
Pressing
P1
selects
A,B,C,D or E.
A,
B, C, D and E correspond with the variables in the chart on the following page.
When you are on the desired variable you would like to change
the setting of press
P2
to change the setting of that variable.
P2
will change the light to 1, 2, 3 or 4 which correspond with the
settings on the chart below on the following page. Below is a list
what each variable controls.
A:
Switches between Function Logics. Function Logics are sets of
actions that will occur when an accessory terminal connection is
made or disrupted. Each set of actions is designed to give different
results providing increased safety, convenience or other.
B: Switches between the amount of time the gate pauses
before closing after reaching full open. By selecting Logic EP
(4) all pause times will be void and the gate will remain open
until an opening devices is triggered.
C: Switches between the amount of time the gate waits before beginning motion
when an opening and closing is triggered or if dual gates are installed, pause time will
only apply to one gate.
D: Switches between the amount of force the gate opener will exert before an
obstruction is detected and the gate reverses directions.
E: Switches between the speed of the gate motion. This does not effect the soft
start and stop.
See the following page for Gate Movement Variables LED
Chart .
Controlling the Master Leaf with either the Master or Slave
Control Board
With this function you can select the leaf you wish to move with the Master Control
Board. Press and hold down
P1,
then press and hold down
P2.
LED A starts flashing.
Using
P2
move from LED 1 to LED 2 according to the desired leaf control as described
below:
LED 1
lit - Master controls leaf 1 (default)
LED 2
lit - Master controls leaf 2
N O T E :
The operation of the Slave Control Board is automatically set according to the Master Control Board.
Summary of Contents for Sentry Swing