In upper picture 1.0.M means the hard drive is attached to Adapter 1, Channel 0, and
the drive is set to Master. The following is a list of all possible combinations:
1.0.M
1.1.M
1.2.M
1.3.M
Serial ATA
Adapter 1, Channel 0, Master
Adapter 1, Channel 1, Master
Adapter 1, Channel 2, Master
Adapter 1, Channel 3, Master
2.1.M
2.2.M
Adapter 2, Channel 1, Master
Adapter 2, Channel 2, Master
NOTICE
There is no such thing as Slave drive in Serial ATA. All drives are considered
to be Master since there is a one to one connection between the drive and
the controller.
5.1.3.2 Using the Define a New Array Window
If necessary, press the tab key to move from field to field until the appropriate field is
highlighted.
Selecting the RAID Mode
By default, this is set to Mirroring. To change to a different RAID mode, press the down
arrow key until the mode that you want appears in the RAID Mode box-either Mirroring,
Striping, Spanning, or Stripe Mirroring.
Selecting the Striping Block Size
Striping block size is given in kilobytes, and affects how data is arranged on the disk.
It is recommended to leave this value at the default Optimal, which is 32KB, but the
values can be between 4 KB and 128 KB.
Assigning the Disks
The disks that you enabled from the RAID Config BIOS setup page appear in the Free Disks
block. These are the drives that are available for use as RAID array disks. To designate
a free disk to be used as a RAID array disk,
①
Tab to the Free Disks section. The first disk in the list is selected
②
Move it from the Free Disks block to the Array Disks block by pressing the right arrow
key(
→
). The first disk in the list is moved, and the next disk in the list is selected and
ready to be moved.
③
Continue pressing the right-arrow key (
→
) until all the disks that you want to use as RAID
array disks appear in the Array Disks block.
66
Summary of Contents for XtremeServer 1322
Page 1: ...Rev 1 5 1322 ...
Page 4: ...Part I User s Guide ...
Page 25: ... Lower the locking lever and latching it into the fully locked position 23 ...
Page 44: ...4 1 5 9 AMD PowerNow Configuration Submenu 4 1 5 10 Remote Access Configuration Submenu 42 ...
Page 46: ...4 1 5 12 Onboard Device Configuration Submenu 44 ...
Page 47: ...4 1 6 PCI PnP Menu PCI PnP Menu 1 PCI PnP Menu 2 45 ...
Page 51: ...Security Menu 3 Clear User Password Security Menu 4 Boot Sector Virus Protection 49 ...
Page 53: ...4 1 9 1 NorthBridge Chipset Configuration Submenu 4 1 9 Chipset Configuration Menu 51 ...
Page 85: ...XtremeServer ServerDome Agent Xtreme 83 ...
Page 86: ...Part Il Technical Guide ...