APPENDIX B: EXTERNAL COMMUNICATIONS INTERFACE SPECIFICATION
LW250 PULSED Nd: YAG LASER
990-605 REV B: May, 1997
B-17
6.
Contents of Set Data and Monitor Data
(1) Common
Data
Data No.
Item
Data
Range
Units
01
DI Water Temperature
000 - 999
°C
02
Fan Power
00 - 99
%
03
DI Water High Temperature Alarm
00 - 99
°C
04
DI Water Low Temperature Alarm
00 - 99
°C
05
DI Water Resistivity
000 - 999
0.01 M
06
Total Count
00000000 -
99999999
Units
07
Good Count
00000000 -
99999999
Units
(2)
Data Under Each Schedule
Data No.
Item
Data Range
Units
01
Pulse Width
003 - 100
0.1 msec
02
Charge Voltage
200 - 410
Volts
03
Dummy Shot Count
00 - 99
Units
04
Repeated PPS
00 - 10
Units
05
Number of Repeated Shots
000 - 999
Units
06
Upper Limit Setting of Energy Monitor
000 - 999
0.1 J
07
Lower Limit Setting of Energy Monitor
000 - 999
0.1 J
*08
Energy Monitor Value
000 - 999
0.1 J
*9
Average Power Monitor Value
000 - 999
0.1 W
Note:
The values of the data numbers marked with an asterisk (*)
are monitored values. These values can be read but not changed.