Engineering Guide
Space Saver
4
Subject to change without notice.
20.3-TD (1018)
VertiCool Space Saver’
Product Features
The VertiCool “Space Saver” Series of units are small
footprint units� They are available as water cooled, air
cooled (remote condenser or condensing section required),
or chilled water configurations. Additionally the units
are available as standard configurations or they can be
customized for a specific application as a made to order
unit� Individual sections can be utilized with other product
series�
• Water Cooled, Chilled Water or Remote Air Cooled
Configurations
• Cabinets are Galvanized
• Front Access
• Can Be Ducted or Used With a Discharge Plenum
• Fits Through 32” Doorways
• Functionally Run Tested at the Factory
• ½” Fiber Glass Lined Cabinet (Thermal/Acoustical, min�
density of 2 Pounds)
• Sloped Drain Pan in Evaporator Section
• Direct Driven Evaporator Blower (2 & 3 Ton)
• Belt Driven Evaporator Blower (4 thru 15 Ton)
• Ball Bearing Motors
• Resistantly Mounted Ball Bearings fort blowers
• ¾” (2 & 3 Ton) and 1” (4 thru 15 Ton) Blower Shafts
• Cast iron Pulleys and Adjustable Sheaves
• Inherently protected Motors and Compressors
• Adjustable Motor Mounts in Evaporator Section (Belt
Drive Models)
• Copper Tube / Aluminum Fin Coils
• Scroll Compressors
• High and Low Pressure Switches
• Loss of Air Safety Switch (when electric heat used)
• Individual Contactor for each Motor� Compressor and
Stage of Electric Heat
• Adjustable Thermal Expansion Valve with External
Equalizer
• Sight Glass w/Moister Indicator
• Filer Drier
• Draw Through Air Flow (Up To 1" ESP, Except Direct
Drive)
• Single Electric Control Box / Single Point Power
Connection
• High and Low Side Schrader Access Fittings
• Co-Axial Counterflow Heat Exchanger on Water Cooled
Units
• External Filter Rack 2" Filter
Partial List of Options
(Items in BOLD are factory installed):
•
Durable Powder Coated Finish
•
Plenum w/ Discharge Grille
• Condensate Pump
•
Electric Heat or Reheat
•
Protective Coil Coating
•
SCR Controller
•
Drain Pan Overflow Switch
• 2-Way, 3-Way or 350 psig Water Regulating Valves
•
Double Wall Construction
•
Hot Gas Bypass
•
Modulating Hot Gas Bypass
•
Freezestat
•
Return Air Grille
•
External Filter Rack 4" Filter
•
Upgraded Motors
•
Belt Drive (2 & 3 Ton)
•
Hot Gas Reheat
•
Hot Water Coil
•
Steam Coil
•
Compressor Anti-Short Cycle Timer
•
Liquid Receiver
•
Water Side Economizer
• Chilled Water Valve
• Hot Water Valve
• Non-Fused Disconnects
• Thermostats
CONTACT THE FACTORY FOR OTHER OPTIONAL FEATURES
UNIT TYPES, OR VOLTAGES, SUCH AS 575-3-60