Engineering Guide
Space Saver
38
Subject to change without notice.
20.3-TD (1018)
A
TITLE:
2-7 TON VERTICOOL
SPACE SAVER WITH
DUCT CONNECTIONS
DESCRIPTION
ALL PROPRIETARY RIGHTS IN THIS
PURCHASE ORDER/ DRAWING ARE
RESERVED� NO PERMISSION IS
GRANTED TO REPRODUCE THIS
DRAWING IN PART OR IN WHOLE,
OR DISCLOSE ANY OF THE INFOR-
MATION UPON IT TO OTHERS WITHOUT
WRITTEN PERMISSION FROM
UNITED COOLAIR CORP�
SHT: 1 OF 1
-
REV�
NEW
NOT TO SCALE
JAM
JAM
DATE:
DATE:
DATE
BY
ECN#
02/06/07
02/06/07
REV� LEV�
DWG� NO:
-
CA10395
APP� BY:
DWN BY:
SCALE:
7/8" OD
2-3 TON
4-7 TON
1-1/8" OD
WATER CONNECTIONS
REAR VIEW
LH SIDE
IN & OUT
UNITED COOLAIR CORP�
YORK, PA�
SUBJECT TO CHANGE WITHOUT NOTICE
U�S�A�
RH SIDE
FRONT VIEW
3�00
B
3�75
J
3�50
TYP
7�50
3�50 TYP
C
ACCESS PANEL
CONDENSATE
DRAIN
WATER CONN�
(REF� CONN� - AIR COOLED)
POWER IN
ACCESS PANEL
H
G
F
22
4-7 TON
68
OPTIONAL
PLENUM
16
2-3 TON
60
TONS
A
B
5-7/8 11-1/2 17-3/8 13-3/8
14
16-3/4
48
1-7/8 10-1/2 6-5/8
12
14
14-3/8
D
E
F
G
H
J
32
C
P
N
M
K
DUCT
CONNECTION
1�00
1�00
D
E
RETURN
AIR
K
M
P
N
30-1/8 16-1/4 23-1/2 4-1/4
31-3/4 20-1/4
38
5
1) REMOTE CONDENSER OR CONDENSING UNIT IS
REQUIRED FOR AIR-COOLED UNITS�
NOTES:
A
TITLE:
2-7 TON VERTICOOL
SPACE SAVER WITH
DUCT CONNECTIONS
DESCRIPTION
ALL PROPRIETARY RIGHTS IN THIS
PURCHASE ORDER/ DRAWING ARE
RESERVED� NO PERMISSION IS
GRANTED TO REPRODUCE THIS
DRAWING IN PART OR IN WHOLE,
OR DISCLOSE ANY OF THE INFOR-
MATION UPON IT TO OTHERS WITHOUT
WRITTEN PERMISSION FROM
UNITED COOLAIR CORP�
SHT: 1 OF 1
-
REV�
NEW
NOT TO SCALE
JAM
JAM
DATE:
DATE:
DATE
BY
ECN#
02/06/07
02/06/07
REV� LEV�
DWG� NO:
-
CA10395
APP� BY:
DWN BY:
SCALE:
7/8" OD
2-3 TON
4-7 TON
1-1/8" OD
WATER CONNECTIONS
REAR VIEW
LH SIDE
IN & OUT
UNITED COOLAIR CORP�
YORK, PA�
SUBJECT TO CHANGE WITHOUT NOTICE
U�S�A�
RH SIDE
FRONT VIEW
3�00
B
3�75
J
3�50
TYP
7�50
3�50 TYP
C
ACCESS PANEL
CONDENSATE
DRAIN
WATER CONN�
(REF� CONN� - AIR COOLED)
POWER IN
ACCESS PANEL
H
G
F
22
4-7 TON
68
OPTIONAL
PLENUM
16
2-3 TON
60
TONS
A
B
5-7/8 11-1/2 17-3/8 13-3/8
14
16-3/4
48
1-7/8 10-1/2 6-5/8
12
14
14-3/8
D
E
F
G
H
J
32
C
P
N
M
K
DUCT
CONNECTION
1�00
1�00
D
E
RETURN
AIR
K
M
P
N
30-1/8 16-1/4 23-1/2 4-1/4
31-3/4 20-1/4
38
5
1) REMOTE CONDENSER OR CONDENSING UNIT IS
REQUIRED FOR AIR-COOLED UNITS�
NOTES:
TONS
A
B
C
D
E
F
G
H
J
K
M
N
P
2 – 3 Ton
60
16
32
1
7
⁄
8
10 ½
6
5
⁄
8
12
14
14
3
⁄
8
30
1
⁄
8
16 ¼
23 ½
4 ¼
4 – 7 Ton
68
22
48
5
7
⁄
8
11 ½
17
3
⁄
8
13
3
⁄
8
14
16 ¾
31 ¾
20 ¼
38
5
Notes:
(1) Remote Condenser or Condensing Unit is Required for Air-Cooled Units�
Water Connections
In & Out
2 – 3 Ton
7/8" OD
4 – 7 Ton
1-1/8" OD
Unit Dimensions