7. Create OEM Batch – Reads the entire OEM space and prompts the user for a file name to
save a Batch script that can be used to write the entire OEM space back to a reader.
Essentially saves the OEM state to a file so that it can be preserved, and the Batch Access
function in the Register Access menu can be used to restore the state.
Sensors
The Sensors menu is shown in the following figure.
The following are the available Sensor functions:
1. Read – The current sensor registers are queried.
2. ADC – Directly control the ADC
f. Forward
Power
g. Reverse Power
h. Ambient Temperature
i. PA
Temperature
j. Tranceiver
Temperature
k. PA Current
l. Antenna
Sense
3. DAC – Directly control the DAC
a. Tranceiver DAC 0 – Future Use
b. Tranceiver DAC 1 – PA Bias
Mac
Error
The Mac Error menu is shown in the following figure.
25
Copyright 2012 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd.