The Load button queries the current reader and refreshes the values displayed on the
Algorithm Settings page.
To modify the algorithm settings for the current reader, click the Edit button. This opens a
dialog box similar to the one shown in the figure below.
Inventory Algorithm Edit Page
In the Active Algorithm dropdown box, you can select between the Fixed Q and Dyanmic Q
algorithm. When you select a new algorithm, the configurable fields displayed in the center
sub-panel change to match those available with the selected algorithm.
The Activate Select Rules and Active Post-Singulation Rules checkboxes control whether the
select and post singulation criteria that have been configured should be utilized during
inventory, read, write, and similar operations.
Post Singulation Criteria Page
Use the Post Singulation page to view and configure reader settings that define the manner in
which tags and post singulation are filtered (based on all or part of the tag’s EPC).
The figure below shows an example of the page displayed when the Post Singulation Criteria
option is chosen.
Post Singulation Criteria View Page
45