45
7
Appendices
45
Appendices
Chapter
7
■
Protection
■
Calibration setting
Item
number
Setting value name
Setting value range
Default
value
Protection
NOV
RAM
Reference
1
System setting protection
OFF, ON
OFF
◎
2
Calibration setting protection
OFF, ON
OFF
◎
Item
number
Setting value name
Setting value range
Default
value
Protection
NOV
RAM
Reference
1
Zero calibration
-5.000 to 5.000 [V]
0.000
●
◎
2
Rated output
-6.000 to 6.000 [V] (excluding 0)
5.000
●
◎
3
Rated capacity
In case of zero-digit decimal point:
-99999 to 99999 (excluding 0)
In case of one-digit decimal point:
-9999.9 to 9999.9 (excluding 0.0)
In case of two-digit decimal point:
-999.99 to 999.99 (excluding 0.00)
In case of three-digit decimal point:
-99.999 to 99.999 (excluding 0.000)
100.00
●
◎