4.WAY OF CONNECTION
20
4-1-3. How to wire load cell connector
1) Remove a screw (1) indicated in the figure.
2) Turn and remove the lower part of the connector.
3) When looking at the connector (2) from the sol-
dering side, the pin numbers look as indicated in
the right figure.
Wire the connector appropriately in accordance
with a load cell cable you may use.
CAUTION
●
The F805AT-CK can be used only in category II specified by EN61010.
The overvoltage applied to the signal input/output terminals should not
exceed the value defined in category II.
●
The F805AT-CK conforms to the EMC Directive as an industrial environment
product (class A). If it is used in a housing environment, interference may be
caused. In that case, take appropriate measures.
●
The load cell excitation voltage of the F805AT-CK is 5V or 10V. Heating or
breakage may occur unless the load cells maximum excitation voltage is the
load cell excitation voltage of the F805AT-CK or more.
●
When using the F805AT-CK with the four-wire load cell connected, be sure to
connect +EXC and +S, and -EXC and -S. Even if +S and -S are not
connected, normal operation is performed apparently, but heating or
breakage may occur because excessive voltage is applied to the load cell.
(1) Screw
(2)
See from this side
Pin numbers
(2)