![Unipulse F701+ Operation Manual Download Page 52](http://html.mh-extra.com/html/unipulse/f701/f701_operation-manual_843485052.webp)
45
5
Timing Chart for Weighing
45
Ti
m
in
g
C
ha
rt
fo
r W
ei
gh
in
g
Chapter
5
↓
↓
↓
↓
↓
↓
↓
↓
↓
No. Simple comparison control oper-
ation
Checking status
display
Keys for relevant settings
External input signal
to be used
External output
signal to be used
1
ON condition for set point 1
SP1 lights up
Setting mode 0-4: set point 1
Setting mode 0-9: Final
Setting mode 2-1:
Final and over/under comparison
Set point 1 (7 pin) ON
* 1 Set point 1 output is ON when compared weight value
≧
final setting value - set point 1 setting value
2
Operation of the comparison
inhibit timer
Setting mode 1-1:
comparison inhibit time (t0)
* 1 Set point 1 output is ON when compared weight value
≧
final setting value - set point 1 setting value
3
ON condition for set point 2
SP2 lights up
Setting mode 0-5: set point 2
Setting mode 0-9: final
Setting mode 2-1:
final and over/under comparison
Set point 2 (8 pin) ON
* 2 Set point 2 output is ON when compared weight value
≧
final setting value - set point 2 setting value
4
Operation of the comparison
inhibit timer
Setting mode 1-8:
comparison inhibit time (t1)
5
Final - compensation
≦
net
weight
SP3 lights up
Setting mode 0-6: compensation
Setting mode 0-9: final
Setting mode 2-1:
final and over/under comparison
Set point 3 (9 pin) ON
* 3 Set point 3 output is ON when compared weight value
≧
final setting value - compensation setting value
6
Operation of the judging timer
Setting mode 1-2: judging time (t2)
7
Output of complete signal and
output of judging signal
HI, GO or LO lights
up
Setting mode 0-7: over
Setting mode 0-8: under
Setting mode 0-9: final
Setting mode 1-3:
complete output time (t3)
Setting mode 2-1:
final and over/under comparison
Setting mode 2-2:
output selection (22 pin)
Setting mode 2-2:
over/under comparison mode
Setting mode 2-2:
complete signal output mode
Over (10 pin) ON
Under (11 pin) ON
Output selection: GO
(22 pin) ON
Output selection:
complete (22 pin) ON
* 4 The timing of the complete signal output depends on setting mode 2-2: complete signal output mode (shown in the chart as 1: stable and
after the judging timer has elapsed)
* 5
Under is ON when compared weight value
<
final setting value - under setting value
Over is ON when compared weight value
>
final setting value + over setting value
GO is ON when final setting value + over setting value
≧
compared weight value
≧
final setting value - under setting value
* 6 The timing of over/under comparison depends on setting mode 2-2: over/under comparison mode (shown in the chart as 0: compare regu-
larly)
8
After complete output timer has
elapsed
Setting mode 1-3:
complete output time (t3)
Setting mode 2-2:
output selection (22 pin)
Output selection:
complete (22 pin)
OFF
9
Start of next weighing
Setting mode 0-9: final
* 7 After the previous weighing is complete, considered to be ready for the next weighing when the weight value falls below 25% of final.
......