![Unipulse F701+ Operation Manual Download Page 31](http://html.mh-extra.com/html/unipulse/f701/f701_operation-manual_843485031.webp)
24
3
Weighing
24
W
eig
hin
g
Chapter
3
3-5-5.
Moving average filter (Setting mode 4-8)
This filter takes the moving averages of the A/D
converted data and reduces fluctuation of
indicated values. The setting for the moving
average rate depends on the setting for the A/D
convert rate.
3-5-6.
Filter in stable condition (Setting mode 4-7)
This function automatically inserts a digital
filter to reduce fluctuation when the indicated
value is stable.
Stable is defined in motion detection (MD).
3-5-7.
Motion detection (MD) (Setting mode 2-7, 4-7)
Parameters are set to detect indicated value
stability. If the weight value change range is
lower than the set range and this condition
continues longer than the set time, weight value
is considered to be stable and the stable signal
turns ON. Motion detect contains two modes:
stable mode and checker mode.
●
Stable mode
The stable signal immediately turns OFF if
the difference between the weight value and
the current weight value exceeds even a single setting range.
- Compared point (1 second before, 0.95 second before, 0.8 second before, 0.6 second
before and 0.3 second before)
●
Checker mode
The stable signal immediately turns OFF if the difference between the weight value and the current
weight value exceeds even a single setting range.
- Compared point (0.09 second before, 0.06 second before, and 0.3 second before)
A/D 500 times/sec
1 time
←←←←→→→→
512 times
A/D 100 times/sec
1 time
←←←←→→→→
128 times
Response speed
Fast
Slow
Stability of indicated value
Unstable
Stable
[Moving average filter] (Setting mode 4-8)
Signal input range
A/D convert rate500 times/sec: 1 to 512
A/D convert rate100 times/sec: 1 to 128
1: Not insert
0: Insert
[Extended function selection 1] (Setting mode 4-7)
(If inserted, 256 times when the A/D convert
rate is 500 times/sec and 64 times when it is
100 times/sec.)
Filter in stable condition
1: Checker mode
0: Stable mode
[Extended function selection 1] (Setting mode 4-7)
[Motion detect] (Setting mode 2-7)
-
Compared time (0.0 to 9.9 sec)
Change range (00 to 99)
Motion detect mode
Filter block diagram
A/D
(Filter in stable condition)
Analog
filter
Digital
filter
Moving
F701+
Digital
Low pass
filter
load cell
Display
filter
average
and such