Command bit
- Gross weight/net weight display switch Changes gross weight display to net weight display at ON
edge.
Changes gross weight display to gross weight at OFF edge.
- One-touch tare subtraction
Performs tare subtraction at ON edge.
- One-touch tare subtraction reset
Resets tare subtraction at ON edge.
- Digital zero
Turns the gross weight to zero at ON edge.
- Digital zero reset
Resets digital zero at ON edge.
- Hold *1
Holds the current weight value at ON edge.
Releases hold at OFF edge.
- Accumulation clear
Clears the accumulation data at ON edge.
- Accumulation command
Accumulates the current weight value at ON edge.
- Start
Starts weighing at ON edge.
- Stop
Stops weighing and turns the stop signal to ON level at ON
edge. Turns the stop signal to OFF level at OFF edge.
- Pause
Pauses weighing at ON edge.
- Judging input
Rejudges the result at ON edge. Please note that rejudging is
performed when the over/under comparison mode is set to
"external judging input" in sequence mode.
- Zero calibration
Performs zero calibration at ON edge.
- Span calibration (actual load)
Performs span calibration (actual load calibration) at ON
edge.
- Span calibration (equivalent input)
Performs span calibration (equivalent calibration) at ON
edge.
- R/W (R:1/W:0)
Specifies READ/WRITE of command.
READ: Turn ON when reading setting values for F701+.
WRITE: Turn OFF when writing setting values for F701+.
- Command request
Give ON edge when performing read or write command.
- Survival verification request
Change this bit to check whether F701+ is operating
normally. F701+ reverses this bit status in order to output a
response to a survival verification request.