43
5
FUNCTIONS
43
FUNCTIONS
Chapter
5
■
Relationship Between Auto Zero Times, Judging Times,
And Auto Free Fall Compensation
●
When the number of auto zero times is set at 01, auto (digital) zero is applied each time weighing
starts. (For weighing in net weight, tare subtraction is carried out.)
When the number of auto zero times is set at 02 – 99, auto zero is applied for every set times.
When the number of auto zero times is set at 00, the auto zero function is OFF. However, digital
zero and tare subtraction by key operation, external input signal, and Communication are valid.
●
When the number of judging times is set at 01, judgment is made each time weighing ends.
When the number of judging times is set at 02 – 99, judgment is made every set times.
When the number of judging times is set at 00, Over/Under comparisons are not made.
●
Since weight values for auto free fall compensation are sampled at judge-time, the auto free fall
compensation function does not work when no judgment is made.
Auto zero times/ Judging times (Setting code 14,15)
Set the number of auto zero times and the number of judging times in the sequence mode.
* When the number of auto zero times is set at zero, the auto zero at start-time becomes invalid.
* When the number of judging times is set at zero, the sequence becomes equal to
“sequence without judgment”.
■
Sequence Error (Setting Code 86)
If the sequence start signal is input under conditions that weighing cannot be performed properly, or
if the stop signal is inputted during weighing, a sequence error occurs, and weighing cannot be
started until it is canceled. For details of each error, refer to "9-2.Error List" on page 85.
Such a sequence error is canceled by the sequence stop signal or sequence error reset signal.
* When sequence error 3 occurs, the zero alarm also occurs at the same time, but only the sequence
error is canceled. For the method of canceling the zero alarm, refer to "Digital zero reset (Setting
code 83)" on page 24.
* Sequence error reset can also be executed by setting code 86. For the setting method, refer to
for command execution" on page 15.
Set value
Setting range
Initial value
Code No.
AZ times
00 to 99
(0 to 99 times)
01
14
Judging times
01
15
Start
Auto zero
Complete
Judgment
Auto free fall
AZ times
3 times
Judging times
2 times
2 times
Average count of auto free
compensation
fall compensation