49
7
OPTION (Setting Code 38)
49
OP
TION
Chapter
7
■
How to Assemble the Connector
1.
Set the connector and screws (two) into the grooves of the case (one side).
2.
Cover with the other case, and fit the cases.
3.
Tighten the M2×8 pan-head machine screws (two).
Tighten the M2×10 pan-head machine screws (two).
Be aware that washers should be set to the M2×10 pan-head machine screws
(two).
■
Setting Item (Setting Code 38)
BCD output data selection
Setting/
0: Gross weight
1: Net weight
2: Tare weight
3: Ext.
BCD output rate
Setting/
0: 10
1: 20
2: 50
3: 100
4: 200
5: 500
6: 1000 [Times/sec.]
BCD output data form
When the BCD option is mounted, you can select the output data form from BCD and binary.
Setting/
0: BCD
1: Binary
Connector
Pan-head machine screw
M2×8 (short) (two)
Nut M2 (four)
Pan-head machine screw
M2×10 (long) (two)
Washer (two)
Case (two)
Screw (two)
Undefined
BCD output data form
0: BCD
1: Binary
BCD output data selection
0: Gross weight
1: Net weight
2: Tare weight
3: Ext.
BCD output rate [Times/sec.]
0: 10
1: 20
2: 50
3: 100
4: 200
5: 500
6: 1000
Output signal selection
0: Near zero
1: Stable
2: Weight alarm
3: Sequence error
4: Final error
5: Zero alarm