14
3
SETTING PROCEDURE
14
SETTING PROCEDURE
Chapter
3
Example 1) Setting method by alternatives
The F160 handles alternatives by number (numerical value).
Since a number is allocated to the set value you select, input that number referring to "9-1.Setting
Code List" on page 78.
Setting Analog Filter to "0: 2Hz"
1.
From the indicated value display screen, set setting
mode 3 by pressing [FNC]
→
[
][
][
].
2.
Select item number 5 with [
△
]/[
▽
].
The item number and set value are displayed.
3.
Enable change with [
] (The set value flashes.),
and set "0" with [
△
]/[
▽
].
4.
Determine it with [
].
* To cancel the set value change, press [FNC] without
pressing [
] to go back to the set value display.
Example 2) Setting method by numerical value
Setting Balance Weight to 25000
1.
From the indicated value display screen, set setting
mode 4 by pressing [FNC]
→
[
][
][
][
].
2.
Select item number 0 with [
△
]/[
▽
].
The item number and set value are displayed.
3.
Enable change with [
], so that the most significant
digit of the set value flashes.
Set "2" with [
△
]/[
▽
].
4.
Move one digit with [
], so that the second digit
(thousands place) from the most significant digit
flashes.
Set "5" with [
△
]/[
▽
].
5.
Determine it with [
].
* To cancel the set value change, press [FNC] without
pressing [
] to go back to the set value display.
▽
▽
▽
NOVRAM is
being written.
▽
▽
▽
▽
▽
NOVRAM is
being written.