24
5
FUNCTIONS
24
FUNCTIONS
Chapter
5
5-3.
Preset Tare Weight
This function subtracts a preset tare value from the net weight.
This function works when a weight value to be subtracted is input for a tare setting in setting code
09, and tare setting selection in setting code 24 is valid.
Preset tare value (Setting code 09)
Setting range/
00000 to 99999
Initial value/
00000
Preset tare weight (Setting code 24)
Setting/
0: Invalid
1: Valid
5-4.
Digital Zero Regulation Value
(Setting Code 45)
Set a range of zero point adjustment (a gap from the registered Zero Calibration value) by digital
zero or zero tracking. If digital zero operation is performed or zero tracking is actuated where the
digital zero regulation value is exceeded, the “zero alarm” status turns on, and the digital zero
regulation value is subtracted from the gross weight. (Refer to "9-2.Error List" on page 85.)
Setting range/
0000 to 9999
Initial value/
200
5-5.
Digital Zero
Digital zero setting (Setting code 82)
This function forces the gross weight to be zeroed. However, if this operation is performed where
the weight value exceeds the DZ regulation value in setting code 45, the “zero alarm” status turns
ON. The net weight changes according to the following expression: (Net weight) = (Gross weight)
– (Tare weight). Execute digital zero by setting code 82, or turn the digital zero input ON.
Setting/
0: Cancel
1: Execution
Digital zero reset (Setting code 83)
This function resets the digital zero. If this operation is performed with a "zero alarm," the digital
zero is cleared, and the "zero alarm" is released. Execute digital zero reset by setting code 83, or
turn the digital zero reset input ON.
Setting/
0: Cancel
1: Execution