Setup mode
C o n f i g u r i n g
t h e L a p t i m e r
ENGINE SETUP
The engine menu contains all the settings
related to the engine.
ENGINE TIMERS MENU
The engine timer menu contains all the set-
tings related to the five engine timers.
Engine timers menu with timer no. 3 active.
USE TIMER NUMBER
UniGo have five engine timers, but only one of
them is active at a time. You can use one timer
for each of your engines to keep track of the
number of hours used. Remember to change
the timer number when changing engine.
TIMER no. MENU
The timer number 1 - 5 menu contains each of
the engine timers.
Engine number 3 is used for 5 hours and
26 minutes.
Here you can see the timer value, manually
adjust it and reset it.
TIMER no.
The line with the engine timer is used to see
the timer value and manually adjust it. If you
forget to change the engine timer number
when changing the engine, you can add the
time to the correct timer manually.
RESET TIMER
If the engine is rebuild or a new engine is
used, you can reset the engine timer here.
Change the value to Yes and press the
ok
button ( ).
RPM SENSITIVITY
UniGo One have a unique feature to ensure
the best possible RPM signal from the ignition.
Different ignition systems gives different
signals and the mounting of the RPM wire
makes a huge impact on the signal. This can
result in different levels of signals arriving at
the Laptimer. The signal sensitivity in UniGo
One can be adjusted in software.
If you experience drop-out in the RPM graph,
then increase the RPM sensitivity level. If you
experience a noisy RPM graph, then decrease
the RPM sensitivity level.
The value can be adjusted between 0% and
100%. These values are does not reflect zero
signal and full signal, but are adjusted to
reflect the relevant signal range.
RPM FACTOR
The engine stroke is typically only set once.
Adjust it to the stroke of the engine. It can be
set between 1- and 6-stroke. Please notice that
some engines works differently than expected,
so if you see the RPM showing uncorrected
values, try to adjust the RPM factor setting.
RPM SHIFT
When using gears the RPM shift setting is im-
portant. The gear shift indicator is depending
on two settings. The RPM shift value and the
RPM delta value. The RPM shift value is set to
the engine revolution you want to shift gear at.
If you want to shift at 12500 RPM, you need to
Summary of Contents for UniGo One kit 1
Page 6: ...VI This page was intentionally left blank...
Page 10: ...10 I n t r o d u c t i o n Examples...
Page 34: ...34 Setup mode C o n f i g u r i n g t h e L a p t i m e r...
Page 55: ...55 I n d e x...
Page 56: ...Unipro ApS Viborg Hovedvej 24 DK 7100 Vejle Denmark Tel 45 7585 1182 www uniprolaptimer com...