Loading Media/Sensor Calibration for Die-cut Label Printing
STEP 1 of 4
Launch the EDGE2Print software. If your media is die cut, select
Die Cut Mode.
Then select the
Sensor Type.
(We
will use the
Gap Sensor
as the example in the following instructions.)
Note:
If the
Calibrate
button is red, it means the sensor needs calibration before printing.
STEP 2 of 4
Refer to steps 1-8 of “Loading Media for Continuous Printing”
for how to load the roll of media. After the die cut
roll is loaded into the tray, line up the gap of the labels about one inch below the sensor.
Close the left/right media guides. Backwind the roll to ensure there is no tension when the sensor is calibrating. If the
roll is fully wound and has tension on it, it will skew the calibration.
Close the front tray cover and push the tray in.
46