UCD Console for UCD-340 User Manual | Unigraf Oy
22.
Note:
Please note that any change in the captured frame (e.g. clock) will result as a failed test.
Test sets available in the CRC based video test set are
• CRC Based Single Reference Frame Video Test
• CRC Based Single Frame Video Stability Test
• CRC Based Sequence of Reference Frames video Test
• CRC Based Continuous Sequence of Reference Frames Test
CRC Based Single Reference Frame Video Test
The test compares captured frames to a provided reference.
TE compares the video mode (Frame Width, Height, BPP and optionally Frame rate) to
provided parameters and after that captures frames and compares the CRC (check sum) of
their three color components to the provided reference until the number of bad frame limit
provided is detected or the provided total number of frames is reached.
The test is judged FAIL if video mode does not match or the number of bad frames is
exceeded.
The test optionally captures the failed frames as bitmap images and stores them into the
hard disc.
Parameters in use
Test Timeout (default 100 000 ms)
Total number of frames (default 2 000 ms)
Number of bad frames allowed (default 2)
Reference width (default 1920)
Reference height (default 1080)
Reference BPP (default 24)
Expected frame rate (mHz)
Summary of Contents for UCD-240
Page 1: ......
Page 76: ...UCD Console for UCD 340 User Manual Unigraf Oy 76 ...