User manual for NERO TOUCH, NERO TOUCH INSTANT
page 14
Version 1.1 / December 2017
ТМ
4.2 Installation
ATTENTION! A short circuit caused by water! Mortal danger! Vending machine damage.
Never clean the vending machine by watering it from the hose.
Note:
•
Make sure that power supply parameters coincide with characteristics, shown on the vending ma-
chine nameplate, located on the rear side of the casing.
•
The vending machine should be connected to the earthed mains.
•
Don’t use extension cords for connecting the vending machine to the mains.
General requirements for installation
•
Install and operate the vending machine in dry and well-ventilated premises only.
•
The vending machine is not intended for use outdoors.
•
Before commissioning the vending machine, make sure that the ambient air temperature in the
premises, where the vending machine will be operated, is no lower than 10
0
C.
•
When choosing the location for the installation make sure the vending machine will be accessible
for servicing.
• Make sure that the installation surface is flat and stable, without vibrations.
•
Adjust the vending machine level by using the four support feet.
•
The vending machine should be installed on the non slip surface.
•
The outlet for the vending machine mains connection should be easily accessible so that the vend-
ing machine power plug could be rapidly disconnected.
•
The ambient air temperature for the vending machine normal operation should be from 10 to 35
0
С.
•
Make sure that the vending machine rear wall is no less than 80 mm away from the wall.
• • Open the vending machine door and visually check the hydraulic circuit tubes and threaded con
-
nections (see Appendix A). In the case of the hydraulic circuit tube defect or loose connection is
detected the further vending machine use is possible only after the malfunction repair.
Note:
Make sure there’s enough free space in front of the vending machine for fully opening its door.
Installation conditions: Intervals (recommended)
•
The side distance from the objects on the left and right of the vending machine should be no less
than 50 mm (with the exception of the milk cooling module).
•
The distance from the vending machine rear wall should be no less than 80 mm.
• The distance from the floor to the vending machine should be no less than 800 mm.
Installation conditions: Water
•
Make sure that the vending machine is connected to the cold potable water line (in the case of ex-
ternal water supply)!
•
The water line pressure should be from 0.5 to 8.5 bar (0.05 - 0.85 MPa). Pressure exceeding or
lowering is not permitted. If the line pressure is too low or too high, the vending machine will not
operate properly.
•
Water temperature at the vending machine inlet should be from 5 to 35
0
С.
•
The water should satisfy all potable water norms.
•
Don’t bend over the water connecting line.