User manual for NERO TOUCH, NERO TOUCH INSTANT
page 76
Version 1.1 / December 2017
ТМ
9.1.7 Boilers
NAME
DESCRIPTION
VALUE
Minimum coffee temperature
Here the boiler temperature is set. This is the
temperature that the vending machine will hold
immediately after making a coffee-based drink
(as well as after making for a time, specified in
the
Heating delay
setting, considering the
Show
temperatures
setting. If the heating time (the
Heating time setting) is zero, then the boiler is al-
ways holding the temperature specified here.
Enter temperature
Maximum coffee temperature
Here the boiler temperature is specified, which
will be held by the vending machine over the time
(after making the last coffee-based drink), spec-
ified in the
Heating time
setting, plus the time,
specified in the
Heating delay
setting. For instant
vending machines the boiler is always held at this
temperature (if the lower value in this setting is
not zero) because it never brews coffee-based
drinks (i.e. the time from the making of the last
coffee-based drink is infinity).
Enter temperature
Heating delay (in minutes)
Time setting in minutes after the making of last
coffee. The temperature will not rise in accord-
ance with the
Minimum coffee temperature
,
Maximum coffee temperature
and
Heating
time
setting algorithm.
Enter number
Fig.9.17 - Boilers
1