background image

26

The heat stove needs simple and accurate 

cleaning  in  order  to  always  assure  effi  cient 

performance and regular operation. 

During internal heat stove cleaning the fl ue gas fan 

may be started to prevent spilling out the ashes. 

Button 

 and then button   must be pressed 

to actuate this function. The display reads “

PUL 

STUF” (stove cleaning).

To stop the fan just press and hold button   or 

wait for a cleaning cycle to be completed (255 

seconds) . Use the suitable tool to clean the 

burn pot from ashes and any scaling which might 

obstruct the air holes. In the event the pellets 

have run out in the tank, uncombusted pellets 

might accumulate in the burn pot. Always empty 

the burn pot from residues before every ignition. 

Remember that only a correctly positioned 

and cleaned burn pot is able to assure optimal 

ignition and operation of your pellet heat stove. 

When positioning the burn pot, accurately ensure 

its edges fully adhere to its housing and that the 

hole matches the pipe where the resistor is laid. 

There must not be any combustion residues in 

the contact area between the edges of the burn 

pot and the holder's support surface.

BY THE END USER

Daily check-up

Reduced or lack of cleaning may cau-

se failed ignition, resulting in damaging 

the heat stove and the environment 

(possible emissions of non-combusted mate-

rial and soot).

Do not put any pellets that failed to light back 

into the burn pot.

Exchanger cleaning (with stove off )

Scaling acts as insulation and the thicker it is, the 

lower the heat conveyed to water and the structure 

in general. It is therefore very important to clean 

the shell and tube, also called exchanger, to 

prevent scaling and clogging and jamming of the 

cleaning  device.  Just  quickly  push  and  pull  the 

lever 5-6 times so that the springs may remove 

the accumulated soot on the piping.

Check every 2-3 days

 

Clean the compartment around the burn pot (the 

fi re plate) from the ash, pay attention to hot ash. 

Only when the ash is completely cold is it possible 

to also use a canister vacuum cleaner suitable to 

picking up particles of a certain size.

Cleaning ash pan and combustion chamber 

including the igniter duct.

Cleaning the glass

To clean the ceramic glass it is recommended to 

use a dry paintbrush or, in the event of thick dirt, 

the  specifi c  spray  detergent,  use  sparingly  and 

wipe with a cloth.

Do not spray the product on the

painted walls and on the door gaskets 

(ceramic fi bre cord) because

they might be damaged.

Heat stove maintenance and cleaning

.it

 AQ 20/24

.it

 AQ 28/33

Summary of Contents for .it AQ 20

Page 1: ...it AQ 20 24 28 33 INSTRUCTIONS FOR THE INSTALLER USE AND MAINTENANCE...

Page 2: ...elderly disabled and animals The stove must be installed by authorised personnel Authorised Service Centre Diagrams and drawings are supplied as examples in an effort to pursue a policy of constant de...

Page 3: ...resulting from partial or total failure to comply with the instructions contained herein We disclaim all liability resulting from misuse of the stove from incorrect use by the user from unauthor ised...

Page 4: ...with moist hands as it is an electrical appliance Always unplug the cord before operating on the unit The door must always be closed during opera tion Instructions for safe and efficient use The stov...

Page 5: ...pellets If the it remains off for long periods of time the tank must be emptied from any residual fuel Store the pellets away from heat sources and not in humid premises or with explosive atmosphere...

Page 6: ...aria T2 Diametro andata T3 M Diametro Ritorno T4 S valvola sicurezza T5 carico T3 T4 T1 T2 T5 66 5 225 388 284 5 388 156 90 142 245 193 5 128 5 567 283 5 283 5 it AQ T1 flue gas exhaust pipe diameter...

Page 7: ...bo entrata aria T2 Diametro Mandata T3 Diametro Ritorno T4 S valvola sicurezza T5 carico T3 T4 T1 T2 T5 Dimensions it AQ T1 flue gas exhaust pipe diameter T2 air inlet pipe diameter Flow Diameter T3 R...

Page 8: ...96 71 94 56 95 79 94 03 95 79 Average consumption nom red Kg h 4 03 1 08 4 89 1 08 5 58 1 83 6 61 1 83 Heatable surface cu m 350 400 510 600 Flue gas flow rate nom red g s 10 1 4 5 12 9 4 5 15 1 7 9 1...

Page 9: ...ped with external air intake and are not used as bedroom or bathroom and where there is no fire hazard such as garage wood sheds flammable material warehouses in strict compliance with the current rul...

Page 10: ...ere the heat generator is to be installed there must not be any pre existing hoods with extractor or collective type ventilation ducts nor may they be installed Should these appliances be in rooms nex...

Page 11: ...ct qualified personnel who may then be responsible for system conformity according to the provisions of applicable laws System washing In compliance with standard UNI CTI 8065 and to protect the heati...

Page 12: ...kupandcleaning which must be done yearly Ensure a wind proof cowl is installed according to regulations in force Water connections Flue gas exhaust connection Filling up the heat stove After making al...

Page 13: ...and the vertical branch between T fittings change of direction must not be less than 1 5m Check with adequate instruments that there is proper draft The base of the external vertical duct must be fit...

Page 14: ...must be filled from the top of the stove by opening the lid Pour the pellets into the tank To make the procedure easier perform the operation in two steps pour half of the sack content into the tank a...

Page 15: ...clean the glazed door is closed the plug is plugged in and the switch at the rear is in position 1 The LED is on when parameter UT0 1 in the menu is other than OFF thus setting the weekly or daily pro...

Page 16: ...t at Po 9 for the first hours of stove operation To adjust water temperature press button once only The upper display will show the words Set H2o flashing while the water temperature is shown on the l...

Page 17: ...re to prevent detecting incorrect temperatures The probe is located at the rear of the stove When using the internal thermostat it is recommended to always set a slightly higher temperature by a few d...

Page 18: ...ostat e g 18 C the heat stove gets ready for automatic re ignition and then starts operating until reaching 20 C again Regardless of external thermostat operation the heat stove is fitted with an inte...

Page 19: ...o 7 Selection of days of the week when third time is ac tivated UT14 From 00 00 to 23 50 with 10 minute steps Adjust fourth time of heat stove ignition UT15 From 00 00 to 23 50 with 10 minute steps Ad...

Page 20: ...room thermostat does not imple ment the function of cycling the heat stove on and off but sets it to saving mode with buttons and with 10 minute steps Press button to move to the next parameter UT07...

Page 21: ...IL are displayed when the pressure switch is triggered Manually reset water temperature safety thermostat if the water temperature exceeds the safety value set at 100 C heat stove operation stops imme...

Page 22: ...emperature lower than 5 C the circulation pump activates automatically to prevent system freezing it is forbidden to tamper with safety devices The heat stove may be ignited and operation restored onl...

Page 23: ...disconnected Contact the authorised service centre ALAR ALAR ALAR ALAR ALAR ALAR COOL ALAR ALAR ALAR ALAR SERV HOT TEMP The flue gas temperature exceeds 280 C Flue gas probe fault Contact the authoris...

Page 24: ...et filling gearmotor fault The stove continues operating until it processes any pellets in the burn pot after which the display reads Alar No Fire and the stove enters extin ction mode Press the On Of...

Page 25: ...r Cleaning exhaust T Flue gas duct Ash pan holder gasket Internal parts Flue Circulation pump Plumbing components Electrical mechanical components by the user by the TSC authorised technical Support C...

Page 26: ...k up Reduced or lack of cleaning may cau se failed ignition resulting in damaging the heat stove and the environment possible emissions of non combusted mate rial and soot Do not put any pellets that...

Page 27: ...vitrifies If these effects occur it means that the temperatures that have been reached are well above those at which the appliance should work correctly Do not use abrasive or aggressive pro ducts or...

Page 28: ...ignition difficult when it is ignited again in the new season If when the main switch at the rear of the stove is pressed the panel board display does not come on this means that it might be required...

Page 29: ...e stove structure The upper section of the heat exchanger is now free from any encumbrance so it can be cleaned perfectly Once a year it is recommended to also clean the compartment above the exchange...

Page 30: ...st be performed by a skilled technician or by the user who will take on responsibility for them in the event of any damage during maintenance Perform this maintenance with cold heat stove and powered...

Page 31: ...a slight appearance and the tip is not pointing up 1 Poor adjustment which leads to excessive pellet load low fan speed 2 The flue has obstructions or there is pressure hindering regular flue gas exh...

Page 32: ...door is not properly closed or the gaskets are worn 5 Water tank temperature too high 6 Inadequate pellets 7 Poor pellet infeed 8 Combustion chamber dirty 9 Exhaust obstructed 10 Faulty flue gas extr...

Page 33: ...l panel The convection air fan never stops 1 Temperature control probe faulty or defective 2 Faulty fan 1 Check probe operation and if necessary replace it 2 Check motor operation and if necessary rep...

Page 34: ...ary replace it 2 Vent the radiators No hot water is fed out 1 Blocked circulating pump 1 Release the circulating pump The heat stove starts boiling in the modulation stage that is when it reaches the...

Page 35: ...35 Wiring diagram 230V mains filter SCAM THERM OUT...

Page 36: ...more it reserves the right to modify its products as deemed necessary or useful without affecting their essential features 46033 casteldario mantova Italy tel 39 0376 57001 telefax 39 0376 660556 info...