19
The chronothermostat function is used to program
automatic cycling on and off of the heat stove
throughout the week.
To enter programming hold the button for
about three seconds, the upper display will
show the parameter “
UT01
” : press the button
several times and refer to the table below to
program the stove according to your needs. To
exit programming mode at any time press the
button . The chronothermostat parameters are
as follows:
Chronothermostat
Parameter
Description
Settable values
UT01
OFF; Day 1, ...,Day7
Chrono enable and disable.
Set day of the week
UT02
from 00 to 23
Set current hour
UT03
from 00 to 60
Set current minutes
UT04
Reserved
Set technical parameters
UT05
From 00:00 to 23:50 with
10 minute steps
Adjust first time of
heat stove ignition
UT06
From 00:00 to 23:50 with
10 minute steps
Adjustment of first heat sto
-
ve extinction time
UT07
Between on/off for days
from 1 to 7
Selection of days of the
week when first time is ac
-
tivated
UT08
From 00:00 to 23:50 with
10 minute steps
Adjustment of second heat
stove ignition time
UT09
From 00:00 to 23:50 with
10 minute steps
Adjustment of second heat
stove extinction time
UT10
Between on/off for days
from 1 to 7
Selection of days of the
week when
second time is
activated
UT11
From 00:00 to 23:50 with
10 minute steps
Adjust third time of
heat stove ignition
UT12
From 00:00 to 23:50 with
10 minute steps
Adjustment of third heat
stove extinction time
UT13
Between on/off for days
from 1 to 7
Selection of days of the
week when third time is ac-
tivated
UT14
From 00:00 to 23:50 with
10 minute steps
Adjust fourth time of
heat stove ignition
UT15
From 00:00 to 23:50 with
10 minute steps
Adjustment of fourth heat
stove extinction time
UT16
Between on/off for days
from 1 to 7
Selection of days of the
week when fourth time is
activated
UT01: Enable and disable/chronothermostat and
set current day.
This parameter is used to set the current day of
the week or disable programming.
Press buttons and to select the desired
value as shown in the following table:
Example:
if today is Thursday you must select “
Day 4
”,
whereas if you wish to ignite the heat stove
manually (without programming) you must select
“OFF”, in order to disable the chronothermostat.
Press button to move to the next parameter.
UT02: Set current hour
This parameter is used to set the current hour,
press buttons and to select the current
time.
Press button to move to the next parameter.
UT03: Set current minutes
Press buttons and to adjust the current
minutes.
Press button to move to the next parameter.
UT04: Set technical parameters
Press button to move to the next parameter.
UT05: Adjustment of first heat stove ignition time
This parameter indicates the time when you wish
to ignite the heat stove: set the desired time with
buttons and , with 10-minute steps.
Press button to move to the next parameter.
UT06: Adjustment of heat stove extinction time
This parameter indicates the time when you wish
to extinguish the heat stove: set the desired time
Display
Top
MEANING
Day 1
Day 2
Day 3
Day 4
Day 5
Day 6
Day 7
OFF
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Chronothermostat off