11
Water connections
This product has been designed and constructed
to work with closed vessel systems.
The safety valve (T5) discharge must always be
connected to a pipe suitable to withstanding the
high water temperature and pressure,
and be
conveyed to the sewer drain
.
Heat stove connection to the plumbing
system must be SOLELY
carried out
by skilled personnel who are able to
perform installation with perfect workmanship
and complying with the provisions in force in
the country of installation.
The manufacturers disclaim any liability in
the event of damage to property or harm to
persons or failed operation, should the above
warning not be complied with.
Heat stove water connection
.it AQ 20/24
T4
T3
T5
Suggestions for use
If heat stove installation calls for interaction with
another pre-existing system including a heating
appliance (gas boiler, methane boiler, oil fi red
boiler etc.) contact qualifi ed personnel who
may then be responsible for system conformity,
according to the provisions of applicable laws.
System washing
In compliance with standard UNI-CTI 8065
and to protect the heating system from harmful
corrosion, scaling or deposits, it is very important
to wash the entire system before connecting
the heat stove in order to remove residues and
deposits.
After washing the system it is recommended to
use inhibitors to protect it against corrosion and
deposits.
Always install shutoff valves upstream of the boiler,
in order to isolate it from the water system, should
it be necessary to move it in order to perform
routine and/or extraordinary maintenance.
These are all the more useful on the system fl ow
and return piping if the heating system is on a
higher fl oor than the boiler.
The pressure discharge pipe must provisionally
be connected to a jug or funnel to prevent water
from leaking and wet the structure and fl oor in the
event of overpressure.
Safety valve exhaust pipe
.it AQ 20/24
T5
T4
T3
.it AQ 28/33
SYSTEM
FLOW
SYSTEM
FLOW
SYSTEM
RETURN
SYSTEM
RETURN
SAFETY
VALVE
VENT