28
Vermiculite is a mineral with a range of applications
in industry and building for its insulating, thermal
and acoustic properties. In this case Vermiculite
is used to prevent useless heat dispersal. Due
to its fragility it is recommended to handle the
flame breaker with extreme care during cleaning
operations of the combustion chamber and to
clean it exclusively with a soft and dry cloth.
Furthermore, before storing the stove, it is recom
-
mended to completely remove from the tank the
pellets using an ash vacuum cleaner with long
pipe because if the fuel is left inside the stove it
might absorb humidity, pack up and make stove
ignition difficult when it is ignited again in the new
season.
If when the main switch at the rear of the stove is
pressed the panel board display does not come
on, this means that it might be required to replace
the service fuse.
At the rear of the stove is a fuse compartment that
is under the power supply socket.
Open the cover of the compartment with a screw-
driver and replace the fuse (3.15 AT delayed).
Fit the power plug back in and press the main
switch.
Heat stove maintenance and cleaning
Decommissioning
When not in use the heat stove must be
disconnected from the power mains.
For improved safety, especially in the presence
of children, we recommend removing the power
supply cable from the rear.
Cleaning the flame breaker
The heat stove is fitted with a vermiculite element,
the flame breaker.
.it
AQ 20/24
.it