Figure 5-14 Measuring DC Current Lower than 40mA
To measure DC current within 40mA-400mA, do the following:
1. Press
I
button to set measurement type to
DC Current.
2. Press
F3
to select
mA
range, and the measurement unit will display
mA
accordingly.
3.
Plug
mA current module (
UT-M10
)
into input terminalsCOM and V/
Ω
, then turn the switch on the
module to 400mA range.
4.
Insert Black and Red test leads correspondingly into Black and Red terminals on the module.
5. Then connect test leads to tested points, than take the DC current reading.
Figure 5-15 Measuring DC Current within 40mA-400mA
To measure DC current greater than 400mA, do the following:
1. Press
I
button to set measurement type to
DC Current
.
2. Press
F3
to select
A
range, and the measurement unit will display
A
accordingly.
UTD1000L User Manual