Fgiure 5-2 Testing Diode
5.4.3 Testing for Continuity
To check the continutity, do the following:
1. Press
R
to set the measurement type to
Resistance
.
2. Press
F1
button to select
Continutity
.
3. Plug test lead connectors into multimeter input terminals (Black to
COM
and Red to
V/
Ω
).
4. Connect test leads to tested points. The multimeter will beep if tested resistance between tested points
is lower than70
Ω
.
Figure 5-3 Testing for Continuity
5.4.4 Measuring Capacitance
To measure capacitance, do the following:
1. Press
R
to set the measurement type to
Resistance
.
2. Press
F1
button to switch measurement type to
Capacitance
.
3. Plug test lead connectors into multimeter input terminals (Black to
COM
and Red to
V/
Ω
).
4. Connect test leads to the capacitor under test, then take the reading.
Note: To ensure the accuracy, please use the relative mode if test capacitance is
<
5 nF.
UTD1000L User Manual