(2)

 

ID Value 
It is valid when trigger condition is “identifier” or “ID or data”. ID value can be set. 
When ID parity check is set to “yes”, ID range can set to 00~FF. 
When ID parity check is set to “no”, ID range can set to 00~3F. 

(3)

 

Byte Length 
It is valid when trigger condition is “data” or “ID or data”. Set the byte length of data to be triggered. 
Different byte length has different data range. Byte length range can set to 1

8. 

(4)

 

Data 
Set the data to be triggered. It is valid when trigger condition is “data” or “ID & data” and the range is 00

FFFFFFFFFFFFFFFF. 

(5)

 

Error Type 
It is valid when trigger condition is “error”, it can set synchronization, ID parity check and checksum. 
a.

 

Synchronization: synchronizing error 

b.

 

ID parity check: ID parity check error 

c.

 

Checksum: data check and error 

(6)

 

Decoding Setting 
Quickly  enter  the  entrance  of  LIN  protocol  decoding,  refer  to  reference  protocol  decoding 

“LIN 

Decoding”. 

7.20    FlexRay Trigger 

FlexRay decoding trigger can set trigger condition, trigger coupling, trigger mode and trigger setting. 
(1)

 

Trigger Condition 
Set FlexRay trigger condition which includes start frame, indicating bit, identifier, cycle count, header 
field, data, ID & data, end of frame and error. 
a.

 

Start frame

The oscilloscope generates at the start frame of the transmission. 

b.

 

Indicating bit

The waveform generates when the sampled information is in accord with the setting 

indicating bit. 

c.

 

Identifier

The waveform generates when the sampled data is in accord with the setting identifier. 

d.

 

Cycle number

The waveform generates when the sampled cycle number is in accord with the 

setting cycle number. 

e.

 

Header field

The waveform generates when the header field is in accord with the setting header 

field.   

f.

 

Data

The waveform generates when FlexRay protocol samples the data is in accord with the user-

defined  data.  It  can  help  user  quickly  find  the  transmission  signal  of  the  specific  data  that 
interested. 

g.

 

ID and data

The oscilloscope generates when it detects its ID and data is equal to the frame of the 

setting value. 

h.

 

End of Frame

The oscilloscope generates at the end of frame. 

i.

 

Error

The oscilloscope generates at bus error, which includes header CRC error, end of frame CRC 

error, empty frame static error, empty frame dynamic error, synchronizing frame error and start 
frame error.   

Summary of Contents for UPO2102

Page 1: ...User s Manual MSO UPO2000 Series Digital Phosphor Oscilloscope...

Page 2: ...Technology China Co Ltd All rights reserved Trademark Information UNI T is the registered trademark of Uni Trend Technology China Co Ltd Document Version MSO UPO200020220624 V1 00 Statement UNI T pro...

Page 3: ...If the product is shipped domestically to the location of the UNI T service center UNI T shall pay the return shipping fee If the product is sent to any other location the customer shall be responsib...

Page 4: ...herwise specified in the product manual Safety Statement Warning Warning indicates the presence of a hazard It reminds users to pay attention to a certain operation process operation method or similar...

Page 5: ...lar equipment such as electronic instruments and electronic equipment electronic equipment with protective measures and any high voltage and low voltage circuits such as the copier in the office CAT I...

Page 6: ...avoid fire and impact of excessive current Please consult the product manual for detailed rated values before connection Use the power cord properly You can only use the special power cord for the ins...

Page 7: ...d dry environment with ambient temperature from 0 to 40 Do not use this device in explosive dusty or humid air Do not operate in humid environment Do not use this device in a humid environment to avoi...

Page 8: ...n of AC power supply that can input Voltage Range Frequency 100 240VAC Fluctuations 10 50 60Hz Please use the attached power lead to connect to the power port Connecting to service cable This instrume...

Page 9: ...lloscope that is easy to use with excellent technical specifications a perfect combination of many functionalities that can help users to quickly complete testing MSO UPO2000 series is aimed at satisf...

Page 10: ...ltiple channels independent trigger fluorescent display Multiple channels with independent hardware 7 digits frequency meter DVM supports multiple channels independent AC DC TRMS true virtual value me...

Page 11: ...Guide This chapter introduces on using the oscilloscope for the first time the front and rear panels the user interface as well as the built in help system General Inspection Before Use Front Panel Re...

Page 12: ...distributors UNI T will arrange maintenance or replacement 4 2 Before Use To perform a quick verification of the instrument s normal operations please follow the steps below 1 Connect to the Power Sup...

Page 13: ...on the probe to 10x and connect the probe to CH1 Make sure the probe s connector is properly connected with theoscilloscope Connect the probe s main clip and ground clip to the oscilloscope s compensa...

Page 14: ...key 10 Clear all control key 11 Compensating signal connector and ground terminal 12 Factory setting LA 16 digital channel AWG function arbitrary waveform generator protocol decoding Print Screen key...

Page 15: ...240 V 50 60Hz 7 Power Switch Turn on power switch after AC socket is connect properly the oscilloscope can be power on normally Press power supply soft key on the front panel to boot the oscilloscope...

Page 16: ...e channel moves to left or right Horizontal position parameter will display on the top of the screen in real time Press this knob to return the channel display back to the midpoint position Horizontal...

Page 17: ...n orange 7 Clear All Press this key to clear all the recalled waveform on the screen If the oscilloscope is in RUN state then keep refresh new waveform 8 PrintScreen Press this key to save waveform as...

Page 18: ...ay setting menu It can set waveform display type grid type grid brightness waveform brightness background brightness duration color temperature anti color temperature pop up window transparency and de...

Page 19: ...ate press this key to playback waveform press it again to pause playback Record Press this key to start recording waveform 14 HOME Menu Tap HOME icon to pop out HOME shortcut menu list as show in Figu...

Page 20: ...age depth of the current scale 4 Waveform indicator 5 Waveform trigger position Display the trigger position of the current waveform 6 Horizontal displacement Display the horizontal displacement value...

Page 21: ...al scale Display vertical scale of CH1 when CH1 is activated This parameter can be changed by using SCALE knob on vertical control area d Probe attenuationfactor Display probe attenuationfactor of CH1...

Page 22: ...state ON or OFF b Source Set the measuring source of multimeter which can set to CH1 CH2 CH3 or CH4 c Mode AC DC AC DC 12 Help Tap help icon in HOME menu to enter help menu 13 Analog channel icon and...

Page 23: ...gure 4 9 Squeeze Gesture 3 Drag Use one finger to press and drag the selected item to the aimed position as shown in Figure 4 10 Drag gesture can use for Drag waveform to change waveform displacement...

Page 24: ...perating waveform mode is opened Operating waveform mode of the oscilloscope is enabled by default 5 Touch shortcut operating Separate two fingers and meanwhile slide two fingers to one direction this...

Page 25: ...ral options This symbol represents that there has next menu This symbol represents that the menu has two options This symbol represents that multipurpose knob and jog dial on the front panel can be us...

Page 26: ...annel 4 analog channels are CH1 CH4 Vertical channel setting method of each channel is quite the same 2 analog channels are CH1 CH2 In this chapter take 1 channel 1 as example to introduce vertical ch...

Page 27: ...Channel Coupling Set channel coupling mode in channel which can select to DC direct current AC alternating current and ground DC AC Ground 5 3 Bandwidth Limitation The bandwidth limit can set to 20 MH...

Page 28: ...se Set the reverse phase in channel When reverse phase is turned on the voltage value of waveform will be reversed and the reverse icon will display on the screen as shown in Figure 5 2 Figure 5 1 Rev...

Page 29: ...User s Manual MSO UPO2000 Series 29 137 Instruments uni trend com 6 Horizontal System Horizontal Scale ROLL Mode Window Extension XY Multi Scopes Trigger Holdoff...

Page 30: ...ng the horizontal time base the scale information will appear in the upper left corner of the screen as shown in Figure 6 1 it changes in real time Figure 6 1 When the time base is changing waveform w...

Page 31: ...ss fail test parameter measurement recording waveform and waveform brightness cannot be used 6 3 Window Extension Window extension is used for magnifying a waveform to view the image detail Window ext...

Page 32: ...le XY supports cursor measurement it can quickly measuring the phase difference between two channels as shown in Figure 6 5 1 Format of Time Base a YT Display voltage value on time base horizontal sca...

Page 33: ...dinate product and proportion in sequence below Cursor Time rectangular coordinate polar coordinate product and proportion in sequence below Cursor Delta numerical difference between two cursors in se...

Page 34: ...phase relation of the two signals based on the Figure 6 7 Figure 6 7 6 5 Multi Scopes In multi scopes CH1 CH4 can be set to different time base scale so that signals of different frequency in multiple...

Page 35: ...for viewing complicated waveform such as pulse string Holdoff time refers to the time that the oscilloscope waits to restart the trigger circuit During hold off the oscilloscope will not trigger unti...

Page 36: ...ntil the trigger condition is met When a trigger is detected the oscilloscope continuously collecting enough data to draw the waveform at the right side of the trigger point In this chapter take 4 ana...

Page 37: ...f trigger modes auto normal and single a Auto trigger When there is no trigger signal the system automatically collect and display data When the trigger signal is generated it automatically switch to...

Page 38: ...of pretrigger and delay trigger information Horizontal move the waveform to view more pretrigger information By observing the pretrigger data the waveform before generated can be observed For example...

Page 39: ...shown in Figure 7 2 Figure 7 2 1 Condition Select trigger condition a It will be generated when the pulse width of the trigger signal is greater than the pulse width setting it can set the lower limit...

Page 40: ...d The TV scan line is 525 lines The even field is in the front and the odd field is in the rear c SECAM The frame frequency is 25 frames per second the TV scan line is 625 lines interlaced scanning 3...

Page 41: ...t of time c It will be generated when the slope time of the trigger signal is basically similar to the setting slope time or the pulse width of the trigger signal is in the setting scope it can set th...

Page 42: ...Trigger Polarity a Positive pulse Set to trigger on the positive runt pulse b Negative pulse Set to trigger on the negative runt pulse 2 Condition Trigger condition Irrelevance a Irrelevance Does not...

Page 43: ...in Figure 7 5 Over amplitude pulse trigger menu can set source coupling mode trigger mode over amplitude type rising edge falling edge random edge position enter exit time trigger setting level setti...

Page 44: ...knob on trigger control area to quickly switch the selection a Low level Adjust low level threshold of ramp trigger by using LEVEL knob on trigger control area b High level Adjust high level threshol...

Page 45: ...and lower limit of time d It will be generated when the time difference T between the edge of source 1 and the edge of source 2 is smaller than the setting lower limit of time or greater than the sett...

Page 46: ...the trigger condition by looking for the duration of the specified codes The codes are the combination of channel logic AND and the value of each channel can be H high L low or X ignored It will be g...

Page 47: ...red when the condition is met The range can be set to 8ns 10s 7 11 Setup Hold Trigger In setup hold trigger the oscilloscope need to set up the data signal line and clock signal line The setup time be...

Page 48: ...ime of pattern with the setting time of T it will be triggered when the condition is met The range can be set 8ns 10s 7 12 Nth Edge Trigger The Nth edge trigger is triggered on the Nth edge after the...

Page 49: ...nnels are judged true i e the actual pattern is consistent with the preset pattern type the oscilloscope will trigger on the specified edge If the edge is not assigned the oscilloscope will trigger at...

Page 50: ...ation process and quickly find the transmission process of parity error so that you can easily locate the fault analysis d Data The trigger is generated when the data acquired by the oscilloscope is t...

Page 51: ...t will be generated when the addresses are the same and the data relationship meets the setting conditions during the transmission process This trigger condition makes it easy to implement the I2 C sp...

Page 52: ...1s 4 Decoding Setting Quickly enter the entranceof SPI protocoldecoding refer toreference protocoldecoding SPIDecoding 7 17 CAN Trigger CAN decoding trigger can set trigger condition trigger coupling...

Page 53: ...s 1 8 6 Data Set the data to be triggered It is valid when the trigger condition is data or ID and data the length byte of data is related to byte value and the range is 00 FFFFFFFFFFFFFFFF 7 Decoding...

Page 54: ...c Bias Set the data bias of byte data for delay trigger it can set on or off when it is on display the byte bias menu and the bias range is 0 63 when it is off hide the byte bias menu 5 Decoding Sett...

Page 55: ...trigger setting 1 Trigger Condition Set FlexRay trigger condition which includes start frame indicating bit identifier cycle count header field data ID data end of frame and error a Start frame The o...

Page 56: ...menu the biased range is 0 253 OFF biased data menu will be hidden 8 Frame Type It is valid when the trigger condition is end of frame The frame can be static dynamic or all frame a Static frame It wi...

Page 57: ...on and the two regions support setting the corresponding enable sources CH1 CH2 CH3 CH4 1 Rectangle drawing menu can set region A enable source A region B enable source B a Region A enable Set whether...

Page 58: ...enu Or it can touch the horizontal position and vertical position of region trigger frame in moving area to adjust the waveform s time base scale volts div scale The region trigger frame will extend a...

Page 59: ...User s Manual MSO UPO2000 Series 59 137 Instruments uni trend com 8 Automatic Measurement Parameter Measurement Automatic Measurement Menu All Parameter Measurement User defined Parameter...

Page 60: ...the sum of the voltage values at the top and bottom of the waveform Pk Pk Peak to peak value the voltage value from the highest point to the lowest point of the waveform Amp Voltage from top to bottom...

Page 61: ...e 2 FFLR Time from the last falling edge of source 1 to the last rising edge of source 2 FFLF Time from the last falling edge of source 1 to the last falling edge of source 2 Other Duty Ratio of posit...

Page 62: ...and minimum Only enabled when user defined parameters display on the screen Difference Automatic calculates and displays the current user defined parameters the average standard deviation and measure...

Page 63: ...o large or too small 8 4 User defined Parameter Press MEASURE to pop out user defined menu as shown in Figure 8 2 Figure 8 2 Rotating the Multipurpose knob to select parameter and press the knob to co...

Page 64: ...ents uni trend com 9 Cursor Measurement The cursor can be used to measure the X axis value time and the Y axis value voltage of the selected waveform Press the CURSOR button to enter the cursor measur...

Page 65: ...adjusting the horizontal position of A and B to achieve time measurement 9 2 Voltage Measurement Voltage measurement is the same as time measurement the difference is the vertical cursor of time measu...

Page 66: ...ments uni trend com 10 Sampling System Sampling is convert signal of analog input channel to discrete point via analog digital converter ADC Press ACQUIRE key on the front panel to enter sampling menu...

Page 67: ...ge of timing scale and storage depth MSO UPO2000 oscilloscopes sampling rate is displayed in real time in the status bar on the top of the screen The horizontal SCALE knob can adjust the horizontal ti...

Page 68: ...ng interval and these values to display the waveform The oscilloscope can acquire and display a narrow pulse otherwise the narrow pulse might be missed in the normal mode Noise might be enlarged in th...

Page 69: ...e number of waveform that can be stored in the oscilloscope during a trigger acquisition It reflects the memory storage capacity of the acquisition The relation of storage depth sampling rate and wave...

Page 70: ...se knob jag dial or drag scroll bar to set the grid brightness The default value is 50 5 Backlight Brightness Backlight brightness can be set in the DISPLAY menu rotating multipurpose knob jag dial or...

Page 71: ...cilloscope or external USB storage devices and load the saved settings or waveforms anytime Press the STORAGE key to enter the storage function setting interface Note For the external USB storage devi...

Page 72: ...n Type Waveform Source CH1 CH2 Set which channel waveform to be saved Disk Lock Press save key the waveform will be saved in oscilloscope USB Press save key the waveform will be saved in external USB...

Page 73: ...amplitude scale Remark Only when the oscilloscope is connected to an external USB storage device user can select the disk as USB and then save the settings to the USB storage device When the USB stor...

Page 74: ...lloscope screenshot is saved in the color displayed on the oscilloscope interface Save ink Oscilloscope screenshot will turn the dark background into light color for storage the purpose is saving ink...

Page 75: ...000 Series 75 137 Instruments uni trend com 13 Auxiliary Function Press the UTILITY key to enter the auxiliary function settings menu System Function Recording Waveform Pass Fail Test System Update Bo...

Page 76: ...setting is manual 5 Square Output Square Output can set the output frequency of local square waveform which can set to 10 Hz 100 Hz 1 kHz or 10 kHz The default setting is 1 kHz 6 Frequency Meter Frequ...

Page 77: ...n available subnet mask d Gateway The format is nnn nnn nnn nnn thefirst nnn rangeisfrom1 to233 the secondnnnrange is from 0 to 255 It is recommended that user can consult network administrator for an...

Page 78: ...it will power on directly 15 Option Function Option Function is the entrance of activating option it can select to activate single option as shown in Figure 13 1 or activate all as shown in Figure 13...

Page 79: ...me 5 Quick Record Quick record is continuously recording waveform for improving waveform capture rate in quick record mode the waveform will not displayed on the screen The waveform can only played wh...

Page 80: ...3 Display Information Set whether the test result is display on the right corner of the screen as shown in the following figure Total Wfs represents the total frame number that has tested Pass Wfs re...

Page 81: ...on menu press system key to check the system information to find the model name software and hardware version information b Download the update file from UNI T official website or ask UNI T distributo...

Page 82: ...g the scan the oscilloscope configures the function arbitrary waveform generator output signal and connects to the DUT then compares the DUT input signal with the DUT output signal Each frequency will...

Page 83: ...er which is start frequency stop frequency scanning point amplitude mode amplitude setting DC displacement and source impedance as shown in Figure 13 4 a Start frequency Set start frequency of the sca...

Page 84: ...e range can set to 60Hz 50MHz h Gain display Set whether display gain data and the relevant information in window frame which can set ON or OFF i Phasedisplay Set whetherdisplay phase dataandthe relev...

Page 85: ...ard touch to select or adjust Multipurpose knob to select letter and digit b Storage Save bode diagram s scanned data as the csv format into USB Insert USB to set it c Reload Reload bode diagram s sca...

Page 86: ...rt Example Computer IP 192 168 42 3 Oscilloscope IP 192 168 42 12 PC browser using 192 168 42 12 9000 to access the oscilloscope View the basic information as shown in Figure 13 7 Figure 13 7 Log in t...

Page 87: ...tion of the oscilloscope as shown in Figure 13 9 Figure 13 9 2 Access Outer Network a Plug the network cable into the oscilloscope and the network can be access internet b Open frp proxy service on th...

Page 88: ...ddress subnet mask and gateway click confirmation directly If IP setting is STATIC it should fill in the correct IP address subnet mask and gateway and then click confirmation as shown in Figure 13 11...

Page 89: ...e If each oscilloscope is connect with the same frp server then web_port pic_port ctrl_port of each oscilloscope should be consistent otherwise frp proxy fails and cannot access If frp proxy is modifi...

Page 90: ...signal of analog channel which includes RS232 I2 C SPI CAN CAN FD LIN and FlexRay User can easily find error debug hardware and speed up development progress through protocol decoding It guarantee hig...

Page 91: ...one or two bits In the following description one data string transmission is referred to as one frame as shown in Figure 14 1 Figure 14 1 1 Bus Decoding Bus decoding menu can set bus status display f...

Page 92: ...th parties of communicationshould agree onthe bit rate Usually the bit rate isdefined asthenumber of bits that can be transmitted in 1s For example 9600 bps means 9600 bits can be transmitted in 1s It...

Page 93: ...efer to RS232 Bus Decoding 2 SCL SOURCE Select SCL source to any one of CH1 CH4 or D0 D15 to be clock input of I2 C 3 SDA Source Select SDA source to any one of CH1 CH4 or D0 D15 to be data input of I...

Page 94: ...The high bit of data is transmitted first b LSB The low bit of data is transmitted first 4 CS Source CS source can set any one of CH1 CH4 or D0 D15 to be chip selection input of SPI decoding signal T...

Page 95: ...shold Otherwise it is 0 14 4 CAN Decoding 1 Bus Decoding Refer to RS232 Bus Decoding 2 Information Source Set CAN protocol trigger source which can be CH1 CH2 CH3 CH4 or D0 D15 The current selected so...

Page 96: ...rate when user defined is selected 5 FD Bit Rate Set FD bit rate of CAN FD bus serial data which can select 250k 500k 800k 1M 1 5M 2M 4M 6M 8M and user defined User can input customized bit rate when...

Page 97: ...lexRay Decoding 1 Bus Decoding Refer to RS232 Bus Decoding 2 Information Source Set LIN protocol trigger source which can be CH1 CH2 CH3 CH4 or D0 D15 The current selected source display on the right...

Page 98: ...al operation menu adjusting POSITION or SCALE knob on vertical control area to change the vertical position and the vertical scale of the waveform The math operation waveform cannot be independent adj...

Page 99: ...l Unit The unit of the FFT operation result can select Vrms and dBVrms Vrms and dBVrms display the vertical amplitude size in a linear way and decibel volts way If the FFT spectrum need to display in...

Page 100: ...lay Mode It can set to full screen split screen and waterfall curve for observing spectrum figure a Split screen Display the source waveform and the waveform of FFT spectrum waveform in split screen a...

Page 101: ...display the sampling points of the raw data after FFT operation The display mode can be set to normal average maximum hold and minimum hold The sampling point mode can be set to peak peak average and...

Page 102: ...e interval Reset trace fresh every spectrum data Note A detection trace must be displayed in detecting mode If all detecting mode is not enabled the default setting is normal detecting trace 7 Enhance...

Page 103: ...gital Filter 1 Filter Type a Low pass Only signalwiththesourcefrequency lowerthantheupper limit ofthe current frequency are allowed to pass b High pass Only signal with the frequency higher than the l...

Page 104: ...ession When editingthe expression user can press the delete key to delete clear and application the expression After applying the expression the oscilloscope performs operations according to the expre...

Page 105: ...in Calculating the arcsine of the selected source atan Calculating the inverse tangent of the selected source sinh Calculating the hyperbolic sine of the selected source tanh Calculating the hyperboli...

Page 106: ...intuitively display the logic 1 and logic 0 in figure It s convenient for user to detect and analysis the error in circuit design hardware and software design This chapter is to introduce how to use t...

Page 107: ...light Rotary Multipurpose knob to move the selected channel to the desired position Note Only the channel that have been displayed on the oscilloscope screen and the selected to move the position can...

Page 108: ...sthereference clockof bus Select NULL means not set the reference clock 7 Edge type Set sampling edge type of reference clock which can be rising edge falling edge 8 Display type Select display format...

Page 109: ...The way to input channel label as the following The oscilloscope is mark the corresponding channel with its channel number by default such as For the convenience of using user can set a custom label f...

Page 110: ...en use the oscilloscope to perform the actual measurement transmit delay of probe cable may cause big error zero offset The zero offset is defined as the offset of the intersection of the waveform and...

Page 111: ...arbitrary waveform generator only for MSO S It use direct digital combination technology to generate accurate and stable waveform output with the resolution lower to 1 Hz MSO UPO2000 is economical fu...

Page 112: ...the currently sine wave In different operating mode it may be fundamental wave modulating OFF 3 The on the above figure is waveform reference list Display the parameter of waveform in the list format...

Page 113: ...le channel or output simultaneously form double channel which includes sine wave square wave ramp wave arbitrary wave and noise wave After press AWG key the oscilloscope outputs a sine wave with 1 kHz...

Page 114: ...system default It can adjust the amplitude value and DC offset value of noise by using the Multipurpose knob or numeric keyboard 17 3 Advanced Application AWG can output AM FM Press AWG key to turn o...

Page 115: ...Wave 1 Hz 50 MHz Square Wave 1 Hz 15 MHz Ramp Wave 1 Hz 400 kHz Pulse Wave 1 Hz 15 MHz Arbitrary Wave 1 Hz 5 MHz Set carrier frequency after select the carrier wave Adjusting Multipurpose knob numeric...

Page 116: ...e when the modulating depth is 0 a half of the setting carrier amplitude Output amplitude will change along with modulating wave when the modulating depth is 100 Output amplitude will not over 10 Vpp...

Page 117: ...carrier bandwidth and the system default frequency offset is 100 Hz The frequency value can adjust by using Multipurpose knob or numeric keyboard Frequency offset carrier frequency If the frequency v...

Page 118: ...waveform output arbitrary waveform at a fixed length and frequency in the parameter list by means of automatic software interpolation and sampling point It can adjust Multipurpose knob to Play mode o...

Page 119: ...tion time displacement curve Gamma Gamma signal GateVibar Gate vibration signal LFMPulse Linear frequency modulation pulse MCNoise Mechanical execution noise Discharge Discharge curve OF nickel metal...

Page 120: ...orentz Lorentz function Maxwell Maxwell distribution Rayleigh Rayleigh distribution Versiera Versiera Weibull Weibull distribution ARB_X2 Square function SectMod 5 kind AM Sine segment amplitude modul...

Page 121: ...it cause transient phenomenon of a car ISO7637 2 TP2B Due to boot turn to shut down it cause transient phenomenon of a car ISO7637 2 TP3A Due to the conversion it cause transient phenomenon of a car...

Page 122: ...ACotHCon Cupped arc hyperbolic cotangent function ACotHPro Raised arc hyperbolic cotangent function ACscCon Cupped arc cosecant function ACscPro Raised arc cosecant function ACscHCon Cupped arc hyperb...

Page 123: ...n Minimum 4th Blackman harris window ParzenWin Parzen window TaylorWin Taylaor window Triang Triangle window it s also called Fejer window TukeyWin Tukey window Complex Wavelets 7 kind Complex Frequen...

Page 124: ...ni trend com EGR_2 EGR_3_2 EST_03_2 GaussPulse Gaussian monopulse IAC_1_1 INJ_1_1 INJ_2 INJ_3 INJ_4 INJ_5_6 INJ_7 KS_1_1 Log10 MAF_1_1 MAF_1_2 MAF_5_3 MAP_1_1 MAP_1_2 MC_3 O2PROPA1 O2PROPA2 O2SNAP Rou...

Page 125: ...and CHB Setting Channel output OFF ON Set the status of channel output The default is OFF Channel inverse OFF ON Set the status of channel inverse The default is OFF Load 50 high resistance Set the c...

Page 126: ...User s Manual MSO UPO2000 Series 126 137 Instruments uni trend com 18 Additional Function Key Automatic Setting Run Stop CLEAR Factory Setting...

Page 127: ...green light is on it indicates the RUN state If the red light is on after the key is pressed it is the STOP state In the running state the oscilloscope is continuously acquiring waveform and the uppe...

Page 128: ...izontal midpoint Trigger System Trigger mode Edge Trigger polarity1 Rising edge Coupling mode DC Trigger condition Greater than Lower limit of time 20ns Upper limit of time 20ns Edge count 1 Trigger l...

Page 129: ...FFT mark threshold 0 Digital filter Low pass Measurement Main source of measurement CH1 All parameter measurement OFF User defined parameter OFF Statistics OFF Slave source CH1 Indicator enable OFF In...

Page 130: ...s I2 C address 0 I2 C address mask 0 I2 C operating direction Write I2 C trigger condition ON I2 C byte size 1 I2 C data 0 I2 CC subnet mask 0 SPI CS CH1 SPI CLK CH1 SPI MOSI CH1 SPI MISO CH1 SPI CS P...

Page 131: ...USB DHCP Manual Language The current setting Sampling mode Normal sampling Average sampling time 2 Storage depth Auto Cursor type OFF Cursor mode Independent Horizontal unit of cursor Second Cursor c...

Page 132: ...ll be prompt when the selected reference waveform is not opened in Pass Fail template It will be prompt when turn on operation to run Pass Fail test There is no record data It will be prompt if operat...

Page 133: ...pdating The update file was not fund It will be prompt if USB cannot provide the update file when the instrument is in updating The filename cannot be empty It will be prompt if the filename is empty...

Page 134: ...alid It will be prompt when using Pass Fail test bode diagram reload waveform LA function in FFT split screen waterfall curve mode In FFT split screen mode Pass Fail test is forbidden It will be promp...

Page 135: ...se contact UNI T 3 The measured voltage amplitude value is 10 times larger or smaller than the actual value Check the channel probe attenuation coefficient setting is consistent with the used probe at...

Page 136: ...ripping soft cloth Do not use any abrasive chemical cleaning agent on the instrument or probes Warning Please confirm that the instrument is completely dry before use to avoid electrical shorts or eve...

Page 137: ...5 30pm UTC 8 Monday to Friday or via email Our email address is infosh uni trend com cn For product support outside mainland China please contact your local UNI T distributor or sales center Many UNI...

Reviews: