Quality Tools for Smart Cleaning
Operation of the HydroPower RO
General information
www.ungerglobal.com
20
NOTE
You can adjust the amount of pure water produced by moving the on / off
knob within the blue control range.
Centre position = Recommended working position for an optimal
membrane life.
Below the centre position = less pure water is produced.
Above the centre position = more pure water is produced. The load on
membranes and resin increases, which results in higher consumption
costs.
5 Operation of the HydroPower RO
5.1
General information
Working with the HydroPower RO is only permitted if the operating instructions have been read and
understood.
DANGER
Severe injuries and property damage due to the HydroPower RO falling
are possible.
`
Place the unit on a level surface only.
`
Make sure the unit is stable and will not roll before operating the
system.
`
Wear safety shoes.
CAUTION
Slight injuries due to pressurized containers possible.
`
The 4 filter vessels are pressurized during operation.
`
Never open a filter vessel during operation.
`
Check if the system is watertight before commissioning.
`
Wear protective gloves.