Operation of the HydroPower RO
Controls, buttons and switches
www.ungerglobal.com
www.ungerglobal.com
21
5.2
Controls, buttons and switches
1 Manometer
2 Filter selection buttons
- PRE: Carbon/sediment combi pre-filter
- RO 1: RO membrane 1
- RO 2: RO membrane 2
- DI: DI resin filter
3 Display
4 STOP button
5 On / Off knob
1 2 3
4
5
The navigation in the setup menu is done with the arrow keys next to the display. The current selection is
highlighted in yellow. You can confirm a value or a function with the ENTER key. Press the STOP button to
exit the setting menu.
5.3
The manometer
The manometer shows the water pressure on the
membranes when the pump is running.
Ensure that the water pressure is at least 1 bar. The
optimum is 4 bar, maximum should not exceed 6 bar.
The pump increases the pressure by approx. 4 bar.
Accordingly, the pressure in operation should not exceed 10
bar.
At a pressure of 10.5 bar, the pressure relief valve opens
automatically at the rear.
5.4
The settings menu
To enter the settings menu, proceed as follows:
1. Stop the HydroPower RO with the STOP button.
2. Press the ENTER button to enter the settings menu.
3
You can now view or change all settings.
The main menu allows you to view or change various
parameters such as units of measurement, time / date,
information, software status etc.