Quality Tools for Smart Cleaning
Safety
General safety regulations
www.ungerglobal.com
12
3 Safety
3.1
General safety regulations
3.1.1 Basic principles
Special safety regulations may apply to certain activities. Safety instructions and warnings are given in the
respective sections of the operating instructions.
Operate the HydroPower RO only:
• in accordance with the operating instructions for safety and driving safety
• if the HydroPower RO is in a technically sound condition.
This includes:
• The safety stickers attached to the HydroPower RO must always be complete and in good readable
condition. Renew damaged or unreadable signs.
• Carry out cleaning and maintenance work on the HydroPower RO only if it is disconnected from
electricity.
Turn off the main power switch and unplug the power cord.
• Carry out maintenance on the filter vessels only if they are depressurized.
• Clean the HydroPower RO after use of dirt and impurities.
Use personal protective equipment to avoid personal injury:
`
protective gloves,
`
safety shoes,
`
safety goggles.
3.1.2 Unit protection and warning processes
Overheat protection
If the pump overheats, the overheat protection is triggered automatically and the HydroPower RO switches
off.
Pressure relief valve
If the water pressure in the HydroPower RO is too high (above 10.5 bar), the pressure relief valve opens
at the back of the HydroPower RO and releases excess water through the concentrate hose to reduce the
pressure in the system.