Quality Tools for Smart Cleaning
Preparing for use
Commissioning
www.ungerglobal.com
18
4.4
Commissioning
CAUTION
Slight injuries due to pressurized containers possible.
`
The 4 filter vessels are pressurized during operation.
`
Never open a filter vessel during operation.
`
Check if the hoses and tubes are water-tight and fit properly before
commissioning the system.
`
Use protective gloves.
To start the HydroPower RO, proceed as follows:
1. Connect the power cord to the power supply.
2. Turn on the main power switch
`
The start screen appears.
`
A sequence of images appears in the display, which
reminds you to connect the hoses and bleed the air out
of the HydroPower RO.
3. Connect the hoses.
4. Turn on the water supply and make sure that the unit
is completely filled with water. To check that, press the
yellow pressure buttons. When water comes out, the
vessels are filled.
5. Turn the on / off knob to the green position. The pump
will turn on.
6. Bleed the HydroPower RO by pressing the button on
the front two filters for a few seconds until water is
discharged.