SK00-4167-DI-002-07
22
Measure the tension of the belt
1) Shut down the pump, and be sure to turn OFF the power supply.
2) Remove the belt cover.
3) Set the Ring for Deflection to 5mm.
4) Set the Ring for Load to 0N.
5) Push the center of the belt, between the motor pulley and the pump pulley, down 5mm with
tension meter.
6) Read the load after pushing. It is normal that the load is 30-50N (3-5kgf).
7) If the tension of belt is right, attach the belt cover.
Replace and Re-tension the belt
Summary of Contents for PVD-180
Page 2: ......
Page 11: ...SK00 4167 DI 002 07 7 Fig 4 Dimensional drawing PVD 180B Fig 5 Dimensional drawing PVD 360B...
Page 37: ......