![Ulvac DC-10-D Operation Manual Download Page 76](http://html2.mh-extra.com/html/ulvac/dc-10-d/dc-10-d_operation-manual_4836559076.webp)
DC Power Supply
【
DC-10-D/DC-20-D/DC-10-DH/DC-20-DH
】
6. SERIAL Communication
-67-
Read
Commands
Transmission data
Response data
Write
Commands
Command
Command
Name
Capacity
Description
Capacity
Description
0xE1
READ
FAIL ARC
ABSO
2byte
Detected to FAIL when HARC is detected a set
number of times.
It can be set in steps of 1 time.
0 to 50000 times
→
0 to 50000
50000
:
0xC350
0x69
0xE2
READ
FAIL
ARC RATE
CNT
2byte
Detected to FAIL when HARC is detected a set
number of times within a set time.
It can be set in steps of 1 time.
0 to 50000 times
→
0 to 50000
50000
:
0xC350
0x6A
0xE3
READ
FAIL
ARC RATE
TIME
2byte
ARC RATE CNT setting time.
It can be set in steps of 0.1 s.
0.1s
~
100.0s
→
1
~
1000
1
:
0x0001
1000
:
0x03E8
0x6B
Summary of Contents for DC-10-D