![Ulvac DC-10-D Operation Manual Download Page 16](http://html2.mh-extra.com/html/ulvac/dc-10-d/dc-10-d_operation-manual_4836559016.webp)
DC Power Supply
【
DC-10-D/DC-20-D/DC-10-DH/DC-20-DH
】
2. Overview
-7-
Table 2-5: Control Specifications
Item
Specifications
Cont
ro
l
s
pe
c
if
ic
ati
on
s
Operation
mode*1
LOCL
Operation mode on the unit's front panel
USER
E-model
Cannot be used because USER1 PORT on the back of the Unit is
used for EtherCAT PORT.
Standard
Operation mode using Analog and Digital signals from USER1 PORT
on the back of the Unit.
HOST
E-model
SERIAL communication from the SERIAL communication port on the
back of the Unit (RS-232C or RS-485).
Alternatively, the operation mode is set via EtherCAT communication
from the EtherCAT PORT at the USER1 PORT on the back of the unit.
Standard
Operation mode via SERIAL communication from the SERIAL
communication PORT on the back of the Unit.
(RS-232C or RS-485)
HST+
Operation mode in which USER operation and HOST operation can be used for
each function.
Output control
system
PSEL
Constant power control
ISEL
Constant current control
VSEL
Constant voltage control
Power control
accuracy
(within the
output
range)*2
Less than 1%
to 10% of the
rated power
C-model
Within ±5% of the set value
10% or more
of the rated
power
The higher of the value within ±0.5% of the rating or the value within ±1% of the set
value
*1: The E-model becomes an EtherCAT model as an option.
*2: Under our shipping inspection conditions. The C-model becomes a high-accuracy model as an option.
Table 2-6: Physical Specifications
Item
Specifications
Cooling type
Forced-air cooling system
Outer dimensions
Within 483mm (W) × 630mm (D) × 133mm (H) (*) No protrusions included.
Mass
DC-10-D/DC-10-DH
:
29kg DC-20-D/DC-20-DH
:
36kg
Usage environment
・
1,000m or less above sea level.
・
Avoid direct sunlight, heat, dust, vibration, and corrosive gases.
・
Clean room recommended.
・
Non-condensing.
Temperature: 5 to 40
℃
Humidity, Relative humidity: 35 to 85%
Storage environment
・
No direct sunlight or corrosive gas.
・
Pollution level 2 (No corrosive or flammable gases, no conductive dust, water, oil, or
chemicals)
・
Indoor
・
Non-condensing
Temperature: 0 to 60
℃
Humidity, Relative humidity: 25 to 85%
Certified standards
CE (EN61000-6-2, EN61000-6-4, EN61010-1)
SEMI F47, RoHS-compliant (Europe)
Overvoltage category
Category II
Summary of Contents for DC-10-D