DC Power Supply
【
DC-10-D/DC-20-D/DC-10-DH/DC-20-DH
】
6. SERIAL Communication
-63-
Read
Commands
Transmission data
Response data
Write
Commands
Command
Command
Name
Capacity Description
Capacity
Description
0xAB
READ
ARC
LEVEL
VOLTAGE
2byte
Responds with the voltage-based arc detection
level.
0V, 40V
~
500V
→
0, 40
~
500
40
:
0x0028
500
:
0x01F4
0x2B
0xAC
READ
ARC
LEVEL
CURRENT
2byte
Responds with the current-based arc detection
level.
5A
~
90A
→
5
~
90
5
:
0x05
90
:
0x5A
0x2C
0xAD
READ
HARC
COUNT
4byte
Responds with the cumulative hard-arc detection
count.
The count can be reset by ACT RESET ARC
COUNT (0x2D).
Can be reset.
Totalizing operation continues until a reset is
performed.
The maximum count is 99,999,999.
99,999,999
:
05F5E0FF
0x2D
0xAE
READ
MARC
COUNT
4byte
Responds with the cumulative micro-arc detection
count.
The count can be reset by ACT RESET ARC
COUNT (0x2D).
Can be reset.
Totalizing operation continues until a reset is
performed.
The maximum count is 99,999,999.
99,999,999
:
05F5E0FF
0xC0
READ
ENABLE
LARC
1byte
Responds with enabled/disabled LARC function.
Disabled
:
0x00
Enabled
:
0x01
0x2E
0xC1
Option S
READ SS
1byte
Responds with the SS function.
1
~
5
→
1
~
5
1
:
0x01
5
:
0x05
0x50
0xC2
Option A
READ
ENABLE
STOP
1byte
Responds with the output stop setting during the
arc process.
Disabled (Low-output operation)
0x00
Enabled (Output stop)
0x01
0x51
0xC3
Option S
READ
ENABLE
RCV
1byte
Responds with the setting of automatic recovery
after the arc process.
Disabled (without automatic recovery):
0x00
Enabled (with automatic recovery): 0x01
0x52
0xC4
Option S
READ
RCV
CRNT
2byte
Responds with the current value to be limited
during automatic recovery after ARC processing.
Enter a value 10times larger than the set value.
0.5A
~
5.0A
→
5
~
50
5
:
0x0005
50
:
0x0032
0x53