DC Power Supply
【
DC-10-D/DC-20-D/DC-10-DH/DC-20-DH
】
6. SERIAL Communication
-66-
Read
Commands
Transmission data
Response data
Write
Commands
Command
Command
Name
Capacity
Description
Capacity
Description
0xD6
READ
LAST MARC
COUNT
4byte
Responds with the micro-arc count during the last
output operation.
The maximum count is 99,999,999.
99,999,999
:
05F5E0FF
0xD6
0xD7
READ
ARC
SIGNAL
TIME
1byte
Responds with the time for the arc output signal for
USER1 PORT.
100us
:
0x00
1ms
:
0x01
10ms
:
0x02
100ms
:
0x03
0x5F
0xD8
READ
PARAM
PRESET
1byte
Responds with the PARAM PRESET setting.
NONE
:
0x00
PRESET1
:
0x01
0x60
0xD9
READ
COMM
TERM
1byte
Responds with COMM TERM (RS-485 terminating
resistor ON/OFF).
NO
:
0x00
YES
:
0x01
0x61
0xDA
Option R
READ
RAMP
ALWAYS
2byte
Responds with the rising time of regular output
operation.
If the time is 0ms, the process is disabled.
0, 10ms
~
10000ms
→
0, 10
~
10000
10000
:
0x2710
0x62
0xDB
READ
CONTROL
MODE
CUSTOM
LEVEL
1byte
Responds with the right to make the LEVEL setting.
LOCAL
:
0x00
USER
:
0x01
HOST
:
0x02
0x63
0xDC
READ
CONTROL
MODE
CUSTOM
ONOFF
1byte
Responds with the right to make DC ON/OFF
setting.
LOCAL
:
0x00
USER
:
0x01
HOST
:
0x02
0x64
0xDD
READ
CONTROL
MODE
CUSTOM
OUTPUT
MODE
1byte
Responds with the right to make the OUTPUT
MODE setting.
LOCAL
:
0x00
USER
:
0x01
HOST
:
0x02
0x65
0xDE
READ
CONTROL
MODE
CUSTOM
RESET
1byte
Responds with the right to make the FAIL RESET
setting.
LOCAL
:
0x00
USER
:
0x01
HOST
:
0x02
ANY
:
0x03
0x66
0xDF
READ
CONTROL
MODE
CUSTOM
PARAMETER
1byte
Responds with the right to make the setting for
PARAMETER switching.
LOCAL
:
0x00
USER
:
0x01
HOST
:
0x02
0x67
0xE0
READ
SETPOINT
LOW
1byte
Responds within the tolerance range of 10% or
more of the rating for the setpoint.
2%
~
50%
→
2
~
50
2
:
0x02
50
:
0x32
0x68