DC Power Supply
【
DC-10-D/DC-20-D/DC-10-DH/DC-20-DH
】
6. SERIAL Communication
-52-
Write Commands
Transmission data
Response data
Read
Commands
Command
Command
Name
Capacity
Description
Capacity
Description
0x16
SET
IGNITION
VOLTAGE
2byte
Used to set the limit value of the ignition voltage.
It can be set in steps of 10 V.
200V
~
1500V
→
200
~
1500
200
:
0x00C8
1500
:
0x05DC
1byte
STATUS
0x97
0x18
ACT RESET
Resets the active errors.
1byte
STATUS
0x20
SET
POWER LIMIT
2byte
Used to set the limit value of the output electric
power.
The limit value depends on the P/S configuration.
Enter a value 10 times larger than the set value.
0.3kW
~
240.0kW
→
30
~
2400
30
:
0x001E
2400
:
0x0960
1byte
STATUS
0xA0
0x21
SET
VOLTAGE
LIMIT
2byte
Used to set the limit value of the output voltage.
The limit value depends on the specifications.
200V
~
800V
→
200
~
800
200V
~
1000V
→
200
~
1000 (HV spec.)
200
:
0x00C8
800
:
0x0320
1000
:
0x03E8
1byte
STATUS
0xA1
0x22
SET
CURRENT
LIMIT
2byte
Used to set the limit value of the output current.
Enter the value multiplied by 10 for the set value.
The limit value depends on the P/S configuration.
2.0A
~
600.0A
→
20
~
6000
20
:
0x0014
6000
:
0x1770
1byte
STATUS
0xA2
0x24
SET
PARAMETER
1byte
Set any one of two parameter types: A or B.
When a parameter is changed, the set value is
stored in the currently selected parameter.
This command switches between SET_A and
SET_B.
SET_A
:
0x00
SET_B
:
0x01
1byte
STATUS
0xA4
0x25
Option A
Effective
range
available
SET
MARC ACT
TIME
1byte
Used to set the processing time for micro-arc
detection.
SET MARC ACT TIME HI RES (0x5B) can be
used to set even higher resolution.
100us
0x01
150us
0x02
200us
0x03
500us
0x04
1000us
0x05
2000us
0x06
3000us
0x07
4000us
0x08
5000us
0x09
1byte
STATUS
0xA5