UltraVision Security, Inc. • Salem, New Hampshire 03079 USA • Tel 866.374.9732 • 603.685.0303 • Fax 603.898.1840
www.UltraVisionSecurity.com • [email protected]
Rev 031109
12
Wire
Diagram
CB – Server
CB - CMD
Twisted Pairs
UVSS cable color
ETXD-P
ETXD-P 1 ------------------------------------- 1
White/Orange
ETXD-N
ETXD-N 2 ------------------------------------- 2
Orange
ERXD-P
ERXD-P 3 ------------------------------------- 3
White/Green
ERXD-N
ERXD-N 4 ------------------------------------- 4
Green
48-55V
RELAY-0 5 ----------------------------------- 5
White/Blue
48-55V
RELAY-1 6 ----------------------------------- 6
Blue
GND
12-15V 7 ----------------------------------- 7
White/Brown
GND
GND 8 ----------------------------------- 8
Brown
9 ----------- Not Used ----------- 9
Power Wire Diagram (for daisy-chained concentrator boxes)
48-55V Pos 1----------------------------------------1
Red
48-55V Neg 2----------------------------------------2
Black
GND
3----------------------------------------3
Blue
Shield
4----------------------------------------4
Shield
10.
Squeeze tabs and return red section into black.
11.
Screw backshell onto connector. It may be easier to temporarily connect to a CMD box while
installing the backshell.
12.
Tighten compression nut of backshell to complete Clipper connector installation.
13.
Using a multimeter or similar device, verify continuity of cable. Pin 1 of one end connects to
pin one of the other end, pin 2 to 2, pin 3 to 3, etc. Since the pins are not clearly numbered on
the Clipper connector, it is helpful to use the inner keyed tabs surrounding the pin holes or the
one indented pin for a reference.
If CB to CMD exceeds 110’/33m, crimp the pin 5 wire (wht/blu) with pin 7 (wht/brn), then crimp
the pin 6 wire (blu) with pin 8 (brn) at both ends. Do not use pins 5 and 6.