Allow a remote PC to fully communicate with a Server-8
This resolves 2 symptoms exhibited by the remote PC:
1)
The site map area is all red
2)
Remote switch bank will not work
At the Server-8 PC:
1)
Log out of the UltraSensor application
2)
Stop the service by going to START and select ‘Stop UltraSensor’
3)
Open an Internet Explorer window (it will fail to find the local site)
4)
In the URL area type www.routerlogin.net
5)
Log in using “admin” for user name, “password” for password, without quotation marks then
select OK
6)
On the left column, select “Services”
To correct the map issue;
A)
Select “Add custom service”
B)
In the NAME field type “MapViewer” without quotation marks
C)
If not already displayed use the dropdown menu to select TCP for TYPE (not TCP/UDP)
D)
Type “2201” without quotation marks in both the START AND FINISH PORT fields
E)
Select APPLY (Will display all services in a table)
To correct the switch bank issue (optional, you don’t need to use a remote switch bank)
A)
Select “Add custom service”
B)
In the NAME field type “SwitchBank” without quotation marks
C)
If not already displayed use the dropdown menu to select TCP for TYPE (not TCP/UDP)
D)
Type “2200” without quotation marks in both the START AND FINISH PORT fields
E)
Select Apply (Will display all services in a table)
7)
Select “Rules” on the left column
8)
Under “Inbound Services”, select “ADD”
9)
Scroll through “Service” menu, select MapViewer
10)
For Action use dropdown menu to select “Allow Always”
11)
For LAN type in 10.10.101.254
12)
For WAN use dropdown menu to select ANY
13)
Start and Finish IPs should be all zeros
14)
For LOG use dropdown menu to select NEVER
15)
Select APPLY
16)
Should see new entry in table (HTTPS will also be there and must remain)
If you have a remote switch bank, repeat steps 8 through 16 but select “SwitchBank” instead of
“MapViewer” in step 9.
Scroll down left column to select Logout and Yes to close window. Go to START to Start
UltraSensor.