UltraVision Security, Inc. • Salem, New Hampshire 03079 USA • Tel 866.374.9732 • 603.685.0303 • Fax 603.898.1840
www.UltraVisionSecurity.com • [email protected]
Rev 031109
27
Sensor Specifications
Both the CMD1 and the CMD2 sensors have similar specifications. The primary difference is the
CMD2 is water resistant for outdoor use and is larger in size.
1.
Power ‘on-off’ operable through a standard computer network.
2.
Motion detection of human size objects or larger will trigger the alarm, smaller objects are
eliminated through the “mass threshold” setting.
3.
Detection range is user selectable from 5 to 25 foot (1.5 -8m) radius when buried in earth six
to twelve inches (15-30 cm).
4.
Transmitter Frequency Range: 200 to 600 MHz.
5.
POE power and communications. Standard IP compatibility.
6.
Power, user supplied 240/120 VAC to the network hub, POE is 48 VDC from computer to
concentrator box, then 12 VDC to sensors.
7.
Alarm amplitude sensitivity is factory set and user adjustable, little or no drift.
8.
Automatic self-adjusting for changing background noise.
9.
Laptop on the security network controls the operating parameters (alarm range and sensitivity
level) and monitors operation and communication established, through continuous polling.
10.
Dry switch output that closes on alarm condition can connect to cameras and other alarm
devices.
11.
Operating Temperature Range -10 degrees to 55 degrees C.
12.
The CMD2 is watertight to a depth of one meter.
13.
All sensor software is upgradeable through the Internet.