3-6
3.3
OPERATING PROCEDURE
The control receivers receive control data from the transmitter (i.e. JPD-101,
CTX-800, CCU-100). When the transmitter sends control data with the address
of the receiver, the receiver processes the data and applies the required voltage
to perform the function. For example, when the receiver gets control data with its
address to tilt up, the receiver applies the required voltage on terminal block
TB2, position 2, to energize the motors on the pan and tilt unit to tilt up.
The Model CRX-502 receivers have an expansion board for an additional pan
and tilt unit. If the mother board receives control data with the address of the
expansion board, the mother board sends the data to the expansion board. The
expansion board only receives data if the data contains its address.
The receiver can process the following functions from a transmitter:
•
Pan Left/Pan Right
•
Tilt Up/Tilt Down
•
Zoom In/Zoom Out
•
Focus Near/Focus Far
•
Control (On/Off) Auxiliary Equipment (AUX 1 and AUX 2)
NOTE
To control the auxiliaries in a receiver, the
address of the mother board must be the
control camera on the transmitter.
The auxiliary contacts on the control receiver can be configured as normally
open or normally closed.
Summary of Contents for CRX-501
Page 8: ......
Page 20: ...2 6 ALL MODELS Figure 2 1 MOTHER BOARD PART NUMBER 517484 X040...
Page 21: ...2 7 MODELS CRX 502 AND CRX 520 ONLY Figure 2 2 EXPANSION BOARD PART NUMBER 517482 1040...
Page 31: ...Figure 2 3 MODEL CRX 501 BASIC SYSTEM BLOCK DIAGRAM 2 17...
Page 32: ...Figure 2 4 MODEL CRX 502 BASIC SYSTEM BLOCK DIAGRAM 2 18...
Page 33: ...Figure 2 5 SYSTEM WITH MULTIPLE RECEIVERS AND VIDEO SWITCHER 2 19...
Page 44: ...2 31...
Page 45: ...2 32...
Page 46: ...2 33...
Page 47: ...2 34...
Page 48: ...2 35...
Page 49: ...2 36...
Page 51: ...3 2 Figure 3 1 Mother Board Indicators...
Page 53: ...3 4 Figure 3 2 Expansion Board Indicators...
Page 61: ...4 4 This page left blank intentionally...
Page 63: ...Figure A 1 TYPICAL INSTALLATION FOR CRX 500 SERIES RECEIVER WITH OPTION B1 OR B2 INSTALLED A 2...