2-22
2.7.2
Power Connections.
The control receivers require 120 Vac or 220 Vac 50/60 Hz power.
The unit is labeled for the required power. The power connections
are the same for all models of control receivers.
CAUTION
Make Sure the Power Source And
The CRX-500 Receiver Power
Requirements Are The Same Or
Equipment Damage May Occur.
Run site-specific cabling from an AC source to terminal strip TB4.
Power Source
CRX-500 Receiver
120/220 Vac (Hot)
to
TB4, Terminal 1 (HOT)
Ground
to
TB4, Terminal 2 (GND)
120/220 Vac (NEUT)
to
TB4, Terminal 3 (NEUT)
2.7.3
Pan and Tilt Connections.
CAUTION
Verify The Pan And Tilt Output
Voltage Of The CRX-500 Unit And
The Input Voltage Required For The
Pan And Tilt Unit Are The Same
Before Making Connections.