2-27
2.7.5.3
Selectable Auto/Manual Iris
To be able to select between auto and manual iris,
Option C must be installed in the control receiver and
the lens must be modified to use this option.
Since
each lens is configured differently, you must consult
with the factory before using this option.
The lens ALC output that normally is connected
internally to the lens iris motor must be disconnected.
Then both the ALC output and the iris motor input must
be brought out to the control receiver board. This
includes both sides of the ALC outputs and the motor
inputs.
CONTROL RECEIVER
TB1
SELECTABLE AUTO/MANUAL IRIS
LENS
Terminal 5, LENS -
“Common” side of the lens iris motor
Terminal 4, IRIS
“Drive” side of the lens iris motor
Terminal 6, LENS+
“Drive side of the lens ALC output
Terminal 7, LENS OUT “Common” side of the lens ALC output
2.7.6
Auxiliary Functions
All models of receivers have two contact outputs for controlling auxiliary
devices. The contact outputs are latched contacts that can be configured
as normally open or normally closed.
Summary of Contents for CRX-501
Page 8: ......
Page 20: ...2 6 ALL MODELS Figure 2 1 MOTHER BOARD PART NUMBER 517484 X040...
Page 21: ...2 7 MODELS CRX 502 AND CRX 520 ONLY Figure 2 2 EXPANSION BOARD PART NUMBER 517482 1040...
Page 31: ...Figure 2 3 MODEL CRX 501 BASIC SYSTEM BLOCK DIAGRAM 2 17...
Page 32: ...Figure 2 4 MODEL CRX 502 BASIC SYSTEM BLOCK DIAGRAM 2 18...
Page 33: ...Figure 2 5 SYSTEM WITH MULTIPLE RECEIVERS AND VIDEO SWITCHER 2 19...
Page 44: ...2 31...
Page 45: ...2 32...
Page 46: ...2 33...
Page 47: ...2 34...
Page 48: ...2 35...
Page 49: ...2 36...
Page 51: ...3 2 Figure 3 1 Mother Board Indicators...
Page 53: ...3 4 Figure 3 2 Expansion Board Indicators...
Page 61: ...4 4 This page left blank intentionally...
Page 63: ...Figure A 1 TYPICAL INSTALLATION FOR CRX 500 SERIES RECEIVER WITH OPTION B1 OR B2 INSTALLED A 2...