background image

CRX-501
CRX-510
CRX-502
CRX-520

CONTROL RECEIVER

INSTALLATION AND OPERATION MANUAL

MANUAL NUMBER 517584-1960

Ultrak

® 

, Inc.

4465 Coonpath Road
Carroll, OH  43112
(740) 756-9222

(800) 443-6681

FAX (740) 756-4237

Summary of Contents for CRX-501

Page 1: ...CRX 501 CRX 510 CRX 502 CRX 520 CONTROL RECEIVER INSTALLATION AND OPERATION MANUAL MANUAL NUMBER 517584 1960 Ultrak Inc 4465 Coonpath Road Carroll OH 43112 740 756 9222 800 443 6681 FAX 740 756 4237...

Page 2: ...CED BY ANY MEANS WITHOUT WRITTEN PERMISSION FROM ULTRAK INCORPORATED THE INFORMATION IN THIS PUBLICATION IS BELIEVED TO BE ACCURATE IN ALL RESPECTS HOWEVER ULTRAK INCORPORATED CANNOT ASSUME RESPONSIBI...

Page 3: ...ons changed Table 2 1 on page 2 23 to Table 2 2 Issue 1 Revision F April 1996 Added Model CRX 510 220 X Issue 1 Revision G April 1996 Added CE Warning and Declaration Note As of 1 1 97 this product do...

Page 4: ...imits Are Designed To Provide Reasonable Protection Against Harmful Interference When The Equipment Is Operated In A Commercial Environment This Equipment Generates Uses And Can Radiate Radio Frequenc...

Page 5: ...EDURES 2 3 2 4 PERSONNEL SAFETY 2 4 2 5 SETUP PROCEDURES 2 5 2 5 1 120 VAC OR 220 VAC INPUT POWER 2 8 2 5 2 CAMERA POWER SETUP 2 9 2 5 3 RECEIVER ADDRESS 2 10 2 5 4 TERMINATE RECEIVE COMMUNICATIONS 2...

Page 6: ...8 INSTALLATION DRAWINGS 2 29 SECTION 3 OPERATION 3 1 3 1 GENERAL 3 1 3 2 CONTROLS AND INDICATORS 3 1 3 3 OPERATING PROCEDURE 3 6 SECTION 4 MAINTENANCE 4 1 4 1 GENERAL 4 1 4 2 MAINTENANCE PROCEDURES 4...

Page 7: ...lt Receiver NEMA 1 Indoor D N 517584 1440 2 31 Installation CRX 510 Pan Tilt Receiver NEMA 4 Outdoor D N 517584 5440 2 32 Installation CRX 510 220 X Pan Tilt Receiver NEMA 4 Outdoor 220 Vac Input 220...

Page 8: ......

Page 9: ...ixture of conventional pan and tilt devices and Diamond Electronics FastScan SmartScan units It may also be used as a single digital control system using one transmitter and one receiver The Control R...

Page 10: ...for outdoor installations The outdoor control receivers are housed in a NEMA 4 enclosure Each model provides two auxiliary contacts The auxiliary contacts are latched contacts that can be normally op...

Page 11: ...tions 517588 1040 CRX 502 24 or CRX 502 B 120 Vac Power Input 24 Vac Pan and Tilt Indoor Applications 517588 2040 CRX 502 X or CRX 502 A X 220 Vac Power Input 120 Vac Pan and Tilt Indoor Applications...

Page 12: ...A RECEIVER BOARD OPTION NEMA 4 Outdoor control receiver NEMA 1 Indoor control receiver The data receiver board is used when the control data is sent across the video coax This option requires the UCT...

Page 13: ...s lens or Option C installed in receiver and a lens modified for auto manual iris 6 to 12 Vdc 100 mA adjustable Zoom 6 to 12 Vdc 100 mA adjustable Focus 6 to 12 Vdc 100 mA adjustable Auxiliary Contact...

Page 14: ...18 D 305mm W x 343mm H x 157mm D Weight Model CRX 501 NEMA 1 15 lbs 6 8 kgs Model CRX 510 NEMA 4 17 lbs 7 7 kgs Model CRX 502 NEMA 1 24 lbs 10 9 kgs Model CRX 520 NEMA 4 28 lbs 12 7 kgs Material Outdo...

Page 15: ...mputer oriented environment Maintain the environmental conditions as described in paragraph 1 4 2 2 2 Power and Grounding Requirements a Power Requirements The CRX 500 Series Control Receivers require...

Page 16: ...te goal of any equipment grounding is to ensure personnel safety without sacrificing the stability of reference To be effective grounding must be low impedance at all frequencies This is the foundatio...

Page 17: ...shortage report is to be transmitted to Diamond Electronics immediately b An inspection log is to be maintained with this equipment with all inspection log entries signed and dated by the inspector T...

Page 18: ...tronic equipment unless there is another person nearby who is familiar with the operation and hazards of the equipment and who is competent in administering first aid When the technician is aided by o...

Page 19: ...he expansion board part number 517482 1040 Model CRX 502 and CRX 520 only that may or may not need to be setup prior to power up of the system CAUTION Make Sure That The Power Input Is Correct For The...

Page 20: ...2 6 ALL MODELS Figure 2 1 MOTHER BOARD PART NUMBER 517484 X040...

Page 21: ...2 7 MODELS CRX 502 AND CRX 520 ONLY Figure 2 2 EXPANSION BOARD PART NUMBER 517482 1040...

Page 22: ...er Model CRX 502 and CRX 520 Receivers have an expansion board that has jumpers that must be in the correct positions for 120 Vac or 220 Vac input power WARNING ENSURE POWER IS DISCONNECTED FROM THE C...

Page 23: ...the enclosure for powering two cameras The camera power must be setup for each camera The camera power is setup on the board the camera is connected to WARNING ENSURE POWER IS DISCONNECTED FROM THE C...

Page 24: ...ng DIP Switch S1 on the expansion board All eight positions define the address The switch can be set for addresses 1 through 256 Addresses 1 through 250 can be used by the customer Addresses 251 to 25...

Page 25: ...0 0 1 1 0 8 0 0 0 0 0 1 1 1 9 0 0 0 0 1 0 0 0 10 0 0 0 0 1 0 0 1 11 0 0 0 0 1 0 1 0 12 0 0 0 0 1 0 1 1 13 0 0 0 0 1 1 0 0 14 0 0 0 0 1 1 0 1 15 0 0 0 0 1 1 1 0 16 0 0 0 0 1 1 1 1 17 0 0 0 1 0 0 0 0 18...

Page 26: ...8 7 6 5 4 3 2 1 Power of 2 128 64 32 16 8 4 2 1 Example 1 Camera Number 63 Subtract 1 1 62 Subtract 32 32 Switch 6 OFF 30 Subtract 16 16 Switch 5 OFF 14 Subtract 8 8 Switch 4 OFF 6 4 Switch 3 OFF 2 2...

Page 27: ...rs should be unterminated Mother Board Jumper W4 IN Terminate Receive Communications OUT Unterminate Receive Communications 2 5 5 Lens Zoom Focus And Iris Speed Control Setup The speed of the lens fun...

Page 28: ...wer to the auxiliaries is 120 Vac if the power input is 220 Vac the power to the auxiliaries is 220 Vac Install W10 to provide AC power on Auxiliary Contact 1 Install W11 to provide AC power on Auxili...

Page 29: ...wisted pair shielded cable Carol CO841 or equivalent Diamond Electronics part number 849518 0334 to from terminal strip TB1 for RS 422 control data 2 6 2 Power Input Pan and Tilt Control Lens Control...

Page 30: ...d Electronics part number 849518 0154 _ 12 conductor 18 AWG Belden 8466 or equivalent Diamond Electronics part number 849518 0058 _ 9 conductor 20 AWG Belden 9455 or equivalent Diamond Electronics par...

Page 31: ...Figure 2 3 MODEL CRX 501 BASIC SYSTEM BLOCK DIAGRAM 2 17...

Page 32: ...Figure 2 4 MODEL CRX 502 BASIC SYSTEM BLOCK DIAGRAM 2 18...

Page 33: ...Figure 2 5 SYSTEM WITH MULTIPLE RECEIVERS AND VIDEO SWITCHER 2 19...

Page 34: ...Model JPD 101 Joystick Controller CATS Video Switcher MUX 05 Multiplexer required for multiple JAD 832 control stations CCU 100 Central Control Unit required for multiple JPD 100 control stations Usin...

Page 35: ...e receivers can be controlled from one control point Ten receivers can be daisy chain wired from each output port The total distance of the chain is 4000 feet NOTE Terminate the receive communication...

Page 36: ...ver Power Requirements Are The Same Or Equipment Damage May Occur Run site specific cabling from an AC source to terminal strip TB4 Power Source CRX 500 Receiver 120 220 Vac Hot to TB4 Terminal 1 HOT...

Page 37: ...boards have terminal block TB2 Connect one pan and tilt to TB2 on the mother board and the other pan and tilt to TB2 on the expansion board Run site specific cabling from terminal strip TB2 to the pan...

Page 38: ...0 provide power for two cameras Model CRX 502 and CRX 520 Receivers have two boards in the chassis a mother board and an expansion board Both boards have terminal block TB1 Connect one camera to TB1 o...

Page 39: ...nd lenses Model CRX 502 and CRX 520 Receivers have two boards in the chassis a mother board and an expansion board Both boards have terminal block TB1 If a CRX 501 or CRX 510 Receiver is installed con...

Page 40: ...ard the lens is connected to Option C for Automatic Manual Iris Relay K1 cannot be installed on the board The following connections are made between a motorized manual iris lens and the control receiv...

Page 41: ...tput and the iris motor input must be brought out to the control receiver board This includes both sides of the ALC outputs and the motor inputs CONTROL RECEIVER TB1 SELECTABLE AUTO MANUAL IRIS LENS T...

Page 42: ...uipment as follows NOTE The Form C Relays for the auxiliary contacts are rated at 6 amps AUX 1 TB3 terminal 1 AUX 1 NO Normally open relay contact TB3 terminal 2 AUX 1 NC Normally closed relay contact...

Page 43: ...Installation CRX 510 Pan Tilt Receiver NEMA 4 Outdoor D N 517584 5440 2 32 Installation CRX 510 220 X Pan Tilt Receiver NEMA 4 Outdoor 220 Vac Input 220 Vac Pan Tilt D N 517584 9440 2 33 Installation...

Page 44: ...2 31...

Page 45: ...2 32...

Page 46: ...2 33...

Page 47: ...2 34...

Page 48: ...2 35...

Page 49: ...2 36...

Page 50: ...d CRX 502 receiver 3 2 CONTROLS AND INDICATORS The only controls on the receivers are described in the setup procedures in Section 2 The operational indicators are shown in Figures 3 1 and 3 2 A descr...

Page 51: ...3 2 Figure 3 1 Mother Board Indicators...

Page 52: ...Good data received but does not contain the address of the mother board 3 Good data received with the address of the mother board 2 LED D17 This LED flashes when the pan left function is activated 3 L...

Page 53: ...3 4 Figure 3 2 Expansion Board Indicators...

Page 54: ...data to the expansion board if the data contains the address of the expansion board 2 LED D14 This LED flashes when the TILT DOWN function is activated 3 LED D13 This LED flashes when the PAN RIGHT f...

Page 55: ...X 502 receivers have an expansion board for an additional pan and tilt unit If the mother board receives control data with the address of the expansion board the mother board sends the data to the exp...

Page 56: ...ris Open Close If a motorized manual iris lens or a lens that has been modified for selectable manual automatic iris is installed the iris open close feature of the controller can be used to control t...

Page 57: ...2 Joystick Controller 515616 1960 JPD 100 Joystick Controller 518007 1960 JPD 101 Joystick Controller 518007 2960 CTX 800 Control Transmitter 515829 1913 Must be used with a CCU 100 Central Control Un...

Page 58: ...inor faults before they become serious enough to cause equipment failure As a result major repairs can be avoided and the equipment can be maintained in an operable condition with a minimum of mainten...

Page 59: ...the D1 flash patterns on the mother board Model CRX 502 and CRX 520 receivers have an expansion board LED D1 on the expansion board should be lit when data from the controller is sent with the address...

Page 60: ...ronics for warranty or service repair must have a prior written Authorization to Return Material ARM form completed for its repair Contact Ultrak Inc Service Department 4465 Coonpath Road Carroll Ohio...

Page 61: ...4 4 This page left blank intentionally...

Page 62: ...is installed in outdoor units Option B2 is installed in indoor units The Data Receiver Board Option must be used with a UCT 100 Data Transmitter Unit The RS 422 control data to control the pan and ti...

Page 63: ...Figure A 1 TYPICAL INSTALLATION FOR CRX 500 SERIES RECEIVER WITH OPTION B1 OR B2 INSTALLED A 2...

Page 64: ...Transmitter RG 59 Coaxial Cable is for runs less than 800 feet 2 The RS 422 Communication Connections described in paragraph 2 7 1 are not done The RS 422 control data is transmitted over the coaxial...

Page 65: ...mitter Unit If the CRX 500 unit is addressed 1 connect to video input 1 if the CRX 500 unit is addressed 5 connect to video input 5 etc 3 Refer to the UCT 100 Data Transmitter Manual for installing th...