170
TCAJ001
170
10.30
TCAJ001
Anchor Clip Fixing
On PVC external roofs, every glazing bar requires an anchor clip to be installed at the top
end of the bar. The following details show how the anchor clip is fitted to the glazing bar.
1.
Align the drill jig with the end of the glazing bar section at the ridge end of the bar
The anchor clip should be 170mm from the ridge end of the bar.
If the bar is a jack rafter, then the clip will sit lower than 170mm. The angle cut is applied
to the bar followed by the anchor clip fixing.
3.
Place an anchor clip in the magnetic end of the jig and insert into the drilled cavity as
shown below.
2.
Once aligned, drill through the jig using the 10.3mm flute mill bit (TCAD001). Drill
down through the glazing bar teeth, but not through the web.
13