This appliance is intended for domestic use 
and the household environment only.

 

Install and operate the appliance as de-
scribed in the text and illustrations. We do 
not accept liability for damage resulting 
from failure to heed these instructions.

 

This appliance is intended for use up to an 
altitude of 2000 m above sea level.

 

The appliance may only be installed and 
stored in a frost-free room (due to residual 
water).

Risk of electric shock!
Switch off the mains voltage supply 
immediately if a fault occurs.
Immediately shut off the cold water 
supply to the appliance should it leak.

 

The continuous-flow heater may only be 
connected and put into operation by a 
qualified professional.

 

In order to avoid potential sources of 
danger, repairs and maintenance may 
only be undertaken by a suitably quali-
fied specialist.

 

Never open the appliance without discon-
necting the power supply beforehand.

 

The statutory regulations of the respective 
country, as well as those of the local electric-
ity and water suppliers, must be adhered to.

 

The continuous-flow heater is a Class I 
 appliance  and  must be connected to the 
protective earth.

 

The appliance must be permanently 
 connected to installed pipes. The conduc-
tor cross-section must comply with the 
installed appliance power.

 

Caution: Earthed water pipes may give the 
appearance of a connected protective earth.

 

To guarantee compliance to relevant safety 
regulations, an all-pole separator must 
be fitted during installation. The contact 
opening must be at least 3 mm.

 

The continuous-flow heater is only suitable 
for closed (pressurised) operation.

 

The tap and outlet fittings must be ap-
proved for operation with closed (pressur-
ised) continuous-flow heater systems.

 

Only connect the continuous-flow heater 
to a cold water line.

 

The continuous-flow heater is suitable for 
connection to DVGW-tested plastic pipes.

 

Disconnect the electrical connection 
cable from the supply and shut off the 
water supply before connecting the 
appliance!

 

Connect the water supply and then 
 connect the electrical supply.

 

Only make the openings which are re-
quired for installation on the rear of the 
appliance. If the appliance is reinstalled, 
the unused openings must be provided 
with watertight sealing.

 

Do not touch electrically live parts after 
installation.

 

The appliance should be disconnected 
from the electrical mains supply when 
working on the water supply. After service 
work is complete, proceed as during the 
first-time appliance start-up.

 

No changes may be made to the appliance.

 

The appliance may only be used for heat-
ing drinking water for household use.

 

This appliance can be used by children 
aged 8 years and older as well as by per-
sons with diminished bodily, sensory or 
mental perception, or those who lack 
knowledge or experience, if they are moni-
tored or have received instruction concern-
ing use and comprehend the possible dan-
gers that can result. Children may not play 
with the appliance. Cleaning and mainte-
nance by the user
 may not be performed 
by unsupervised children.

 

Keep children away from the appliance.

 

Please monitor children to ensure that they 
do not play with the appliance.

 

The mixer and the warm water pipe may 
be hot. Please inform and instruct children 
appropriately.

 

Do not use aggressive or abrasive cleaning 
detergents!

 

Do not use a steam cleaner.

 

The appliance is only to be descaled by a 
suitably qualified specialist.

Summary of Contents for DH1UF18M

Page 1: ...DH1UF18M DH1UF21M DH1UF24M DE Gebrauchs und Montageanleitung EN Usage and installation instruction ES Instrucciones de uso y de montaje PL Instrukcja u ytkowania i monta u...

Page 2: ...rrichtung vorhanden sein Die Kontakt ffnung muss mindestens 3mm betragen Der Durchlauferhitzer ist nur f r den ge schlossenen druckfesten Betrieb geeignet Armaturen m ssen f r den Betrieb mit geschlos...

Page 3: ...Schrau ben und D beln Unebenheiten der Wand k nnen mit den Stellschrauben ausgeglichen werden IV Wasseranschluss Der Durchlauferhitzer muss entl ftet werden Dazu Warmwasserhahn ganz ffnen und das Ger...

Page 4: ...r MPa bar 0 04 0 4 0 05 0 5 0 06 0 6 Einsatzbereich in W ssern spezi scher elektrischer Widerstand bei 15 C cm 1300 1300 1300 Nenndruck MPa bar 1 10 1 10 1 10 Maximal zul ssige Zulauf Temperatur C 20...

Page 5: ...mit halber Leistung Bei ganz ge ffnetem Warmwasserhahn arbeitet das Ger t mit voller vorgew hlter Leistung E Wassertemperatur erh hen Warmwasserhahn etwas schlie en Bild E 2 E Wassertemperatur senken...

Page 6: ...rch uss ber das Eckventil regulieren lassen Den Durch ussbegrenzer kontrollie ren oder einen kleineren einsetzen Fachmann Die zweite Stufe im Ger t schaltet nicht ein das h rbare Klicken fehlt Das Sie...

Page 7: ...eleistung erfolgt in der Weise dass mangelhafte Teile nach unserer Wahl unentgeltlich instandgesetzt oder durch einwandfreie Teile ersetzt werden Ger te die zumutbar z B im PKW transportiert werden k...

Page 8: ...peration The tap and outlet ttings must be ap proved for operation with closed pressur ised continuous ow heater systems Only connect the continuous ow heater to a cold water line The continuous ow he...

Page 9: ...pensate for any unevenness of the wall s surface IV Water connection The continuous ow heater must be vented Open the warm water tap fully and ush out the appliance thorough ly for 1 minute The ow rat...

Page 10: ...iter MPa bar 0 04 0 4 0 05 0 5 0 06 0 6 Operative range in waters of speci c electric resistance at 15 C cm 1300 1300 1300 Rated pressure MPa bar 1 10 1 10 1 10 Maximum permissible supply temperature...

Page 11: ...ngs When the water tap is turned on fully the appliance will operate at full preselected power E Increasing the water temperature Slightly close the hot water tap Fig E 2 E Decreasing the water temper...

Page 12: ...use the corner valve to regulate the ow rate Check the ow rate limiter or replace it with a smaller one Servicing expert The second stage in the appliance does not switch on the audible clicking is mi...

Page 13: ......

Page 14: ...enbegrenzer in Kaltwasserzulauf einbauen The ow rate limiter must be installed in the cold water supply DH 24kW n e g n e m s s u h c r u D begrenzer rot Flow rate limiter red 9000879392 1 7 2 2 I DH1...

Page 15: ...6 mm 2 6 mm le tro schlu ss lektro schlu ss lektro schl ss Mon tage sch ab lone Mon tage sch ab lone Mon tage sch ab lone Mon tage sch ab lone 2 1 3 3 3 100 4 5 6 7 9 8 II...

Page 16: ...2 2 2 1 1 1 max 16 mm III...

Page 17: ...5 2 4 3 1 IV warm hot caliente gor cy 1 Minute entl ften Vent for one minute Purgar durante 1 minuto Odpowietrzy 1 minut...

Page 18: ...min 40 mm 0 mm PE L3 L2 L1 min 40 mm 2 RESET 1 L1L2L3PE 7 3 5 4 V...

Page 19: ...2 3 4 1 VI L 3 L 2 L 1 3 2 1 PE PE B 1 2 3 4 A...

Page 20: ...G 1 2 A 375 39 472 124 136 236 100 42 204 140 C D 1 2 3 E...

Page 21: ...esta a tierra Al objeto de cumplir con las disposiciones de seguridad pertinentes la instalaci n debe llevar un dispositivo de separaci n omnipolar La abertura de contactos tiene que tener 3 mm como m...

Page 22: ...estar libre de tensi n Quitar o desco nectar los fusibles III Instalaci n mural El calentador de paso continuo ha de montarse de modo que quede perfectamente jo en la pared F jelo con los tornillos y...

Page 23: ...o de aplicaci n en aguas con resistencia el ctrica espec ca a 15 C cm 1300 1300 1300 Presi n nominal MPa bar 1 10 1 10 1 10 Temperatura de entrada m xima permitida C 20 20 20 Clase de e ciencia energ...

Page 24: ...ato funciona en la posici n pre seleccionada con la potencia plena correspondiente E Aumentar la temperatura del agua Cerrar un poco el grifo de agua caliente gura E 2 E Reducir la temperatura del agu...

Page 25: ...vula angular Controlar el limitador de caudal y emplear uno m s peque o Profesional No se conecta el segundo nivel en el aparato no se produce el clic audible Desenroscar el ltro del grifo del agua y...

Page 26: ...bieguny zasilania Rozwarcie styk w musi wynosi co najmniej 3mm Podgrzewacz przep ywowy jest przezna czony tylko do pracy w systemie zamkni tym ci nieniowym Armatury musz by dopuszczone do pracy z zamk...

Page 27: ...towany na sta e na cianie Zamontowa go przy pomocy dostarczo nych ko k w rozporowych Nier wno ci ciany mo na wyr wna za pomoc rub nastawczych IV Przy cze wody Przep ywowy ogrzewacz wody musi by odpowi...

Page 28: ...05 0 5 0 06 0 6 Zakres stosowania dla wody o oporno ci elektrycznej w a ciwej w temperaturze 15 C cm 1300 1300 1300 Ci nienie znamionowe MPa bar 1 10 1 10 1 10 Maksymalna dopuszczalna temperatura dop...

Page 29: ...ci bezpieczniki domowej sieci elektrycznej Zaw r ciepej wody otworzy na tak d ugo a powietrze wypchni te zostanie ca kowicie z przewod w rurowych Bezpieczniki ponownie wkr ci Urz dzenie jest gotowe d...

Page 30: ...pie pracy urz dzenia nie w cza si brak s yszalnego klikni cia Sitko z zaworu wodnego wykr ci i wyczy ci lub usun nagromadzony kamie Klient Wyczy ci sitko w regulacyjnym zaworze k towym rysunek A 4 Spe...

Page 31: ...23...

Page 32: ...BSH Hausger te GmbH Carl Wery Stra e 34 81739 M nchen Germany 6 720 820 345 9001217914 2016 DE EN ES PL...